29 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗E-mails R. Avaltroni 2002
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000160598–000160607
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Further analyses majority of the fibers reported from the PCM analyses are non-asbestos fibers. are being performed to determine the nature of these non-asbestos fibers.
Carbon Monoxide: concentrations A total of 98 air samples were collected for carbon monoxide indicating TWA ranging from 0.16 to 242 ppm. All but 4 of these measurements were below the NIOSH REL of exceeded 35 ppm and all but 1 were below the OSHA PEL of 50 ppm. One sample (242 ppm) the NIOSH recommended ceiling limit of 200 ppm. Additionally, 2 instantaneous peak measurements (1,239 and 1,368 ppm) exceeded the NIOSH immediately dangerous to life or health (IDLH) value of 1,200 ppm and 15 others exceeded the NIOSH recommended ceiling limit of 200 ppm. All carbon monoxide measurements exceeding one or more of these evaluation criteria were being performed by workers using either a cutting torch or a cutting saw. This underscores the need for adequate ventilation and worker awareness when using these tools.
Diesel Exhaust: A total of 8 air samples were collected for diesel exhaust indicating TWA (elemental carbon) concentrations from none detected to 0.023 mg/m3. These measurements are all well below the proposed American Conference of Governmental Industrial Hygienists (ACGIH®) threshold limit value (TLV®) for diesel exhaust of 0.20 mg/m3 (elemental carbon). (NIOSH and OSHA currently have no evaluation criteria for diesel exhaust.)
Freon® 22:
A total of 5 air samples were collected for Freon® 22 (chlorodifluoromethane). No Freon® 22 was detected on any of these air samples.
Hydrogen Sulfide: A total of 10 air samples were collected for hydrogen sulfide. Hydrogen sulfide was detected on only 1 of these samples indicating a TWA concentration of 1.0 ppm and a instantaneous peak concentration of 3.0 ppm. These measurements are well below the NIOSH recommended ceiling limit and the OSHA ceiling limit of 10 ppm.
Inorganic Acids: A total of 27 air samples were collected for inorganic acids including hydrobromic, hydrochloric, hydrofluoric, nitric, phosphoric, and sulfuric acids. Except for sulfuric acid, only trace amounts of inorganic acids were detected on these samples. Small quantities of sulfuric acid were detected on all but 1 of the air samples which were below the NIOSH REL and OSHA PEL of 1.0 mg/m3.
NYC-WTC 000160602
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000160806
Forwarded EPA draft guidance on screening levels for asbestos, fiberglass, and silica in indoor air and settled dust for departmental review.
6 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162015
Forwarded daily environmental summaries from EPA staff to city officials regarding early World Trade Center recovery operations.
10 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159817
Circulation of draft environmental screening benchmarks for asbestos, fiberglass, and silica in indoor air and settled dust for expert review.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160788
DEP discussion of drafting water use exemption notice for contractors performing necessary WTC hazard remediation and facade cleanup work.
6 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141536
Request outlining DEP procurement and EPA supervision of cleaning and sampling contracts for Lower Manhattan residents.
7 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162025
Report on asbestos air sampling at five locations borough-wide, showing levels below residential reoccupancy threshold except at Manhattan site requiring further fiber analysis.
3 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160841
Forwarded summary of calls received at the WTC hotline on April 1, 2002, for agency review and action.
5 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160740
Correspondence between EPA and DEP officials discussing scheduling meetings with building owners to address exterior cleanup issues in late March 2002.
8 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164489
Discussion regarding asbestos sampling results in an apartment and potential release of a draft document.
5 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000164129
DEP transmission of NIOSH industrial hygiene assessment of air quality on WTC debris pile.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164171
DEP transmission of NIOSH summary of broad-based air quality monitoring on WTC debris pile.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149779
Summary of air sampling results and occupational exposure findings from the World Trade Center disaster response.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149779
Summary of air sampling results and occupational exposure findings from the World Trade Center disaster response.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149779
Summary of air sampling results and occupational exposure findings from the World Trade Center disaster response.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Worth Street · 1 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Filed in the same folder
Filed in the same folder
Filed in the same folder
Filed in the same folder
NYC-WTC_000160638
Memo discussing the need to secure full funding from FEMA for indoor air testing and cleanup at the World Trade Center site.
Filed in the same folder