29 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗E-mails R. Avaltroni 2002
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000160598–000160607
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Summary Report to the New York City Department of Health:
NIOSH Air Sample Results for the World Trade Center Disaster Response Centers for Disease Control and Prevention National Institute for Occupational Safety and Health
From September 18 through October 4,2001, National Institute for Occupational Safety and Health (NIOSH) personnel (and contractors) collected air samples in areas immediately adjacent to the debris pile and on persormel actively involved in rescue efforts on or in the vicinity of the debris pile to characterize occupational exposures during the disaster response at the World Trade Center site in New York City, NY. This report is a compilation of sampling efforts that were undertaken over the course of providing technical assistance to the New York City Department of Health (NYCDOH), and were used to identify potential hazards and to recommend appropriate protective measures where needed for the workers whose exposures were sampled. As a result of this activity, workers using acetylene torches to cut metal beams were found to have hazardous exposures to carbon monoxide; this information lead to interventions that addressed the problem. Because these findings are based on limited sampling, they may not be representative of more general exposures. However, they are consistent with those reported by the Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA). The area air samples were collected in the immediate vicinity of workers at a height approximating their breathing zone. The personal air samples were collected on workers with the sampling device placed in the worker’s breathing zone. Additional bulk sampling was conducted and results were included in the daily summaries to the NYCDOH. Blank sampling was also performed for quality assurance; these results are not included in this report.
Asbestos: A total of 827 air samples were collected for asbestos. No fibers were detected in over 50% (455) of these air samples as determined by phase contrast microscopy (PCM). The remaining 372 air samples indicated time-weighted average (TWA) concentrations ranging up to 0.89 fibers/cc as determined by PCM. Twenty-five of these samples exceeded the NIOSH recommended exposure limit (REL) and die OSHA permissible exposure limit (PEL) of 0.10 fibers/cc. In addition, 119 of these air samples were analyzed for asbestos by transmission electron microscopy (TEM), a more sensitive analytical method that can distinguish between asbestos and non-asbestos fibers. No asbestos fibers were detected in over 45% (56) of these air samples as determined by TEM. The remaining 63 air samples indicated TWA concentrations ranging up to 0.063 asbestos fibers/cc as determined by TEM, none of which exceeded the NIOSH REL and the OSHA PEL of 0.10 fibers/cc. These TEM results indicate that the vast 1
NYC-WTC_000160600
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160806
Forwarded EPA draft guidance on screening levels for asbestos, fiberglass, and silica in indoor air and settled dust for departmental review.
6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159817
Circulation of draft environmental screening benchmarks for asbestos, fiberglass, and silica in indoor air and settled dust for expert review.
6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160788
DEP discussion of drafting water use exemption notice for contractors performing necessary WTC hazard remediation and facade cleanup work.
6 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160683
Transmission of WTC-related Q and A document to interagency task force with EPA Regional contact information.
10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160841
Forwarded summary of calls received at the WTC hotline on April 1, 2002, for agency review and action.
5 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000141536
Request outlining DEP procurement and EPA supervision of cleaning and sampling contracts for Lower Manhattan residents.
7 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Worth Street · 1 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000160529
Notice instructing staff to preserve original World Trade Center documents as potential legal evidence and not dispose of them.
Filed in the same folder
NYC-WTC_000160530
DEP memo documenting inconsistent dust control from WTC debris transport trucks affecting school reopening plans.
Filed in the same folder
Filed in the same folder
NYC-WTC_000160536
DEP memo discussing WTC recovery contractor operations, fuel requirements, infrastructure repairs, and school proximity.
Filed in the same folder
NYC-WTC_000160537
Forwarded draft press release from NYC Department of Health regarding WTC environmental and health guidance.
Filed in the same folder