2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗WTC cleanup coordination draft, April 2003
Machine-extracted title · confidence 70%Internal DEP memo forwarding draft document related to post-9/11 environmental cleanup program.
NYC-WTC_000160133–000160134Folder label: “E-MAILS SENT R. AVALTRONI”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
New York City Department of Environmental Protection Asbestos Control Program
66 John Street, Manhattan 9* and 10* Floors
Commissioner Ward received information from NYCDEP employees concerned about the results of a carpet sample taken from the 10* floor of 66 John Street. The Commissioner contacted the Bureau of Environmental Compliance (BEC) and the Safety Office.
The BEC Asbestos Control Program (ACP) received the result of the carpet sonication sample that indicated a concentration of 393,061 structures/cm^. Carpet sonication is not a New York State Department of Health approved method for the collection and analysis of asbestos-containing or asbestos- contaminated material. Further, this sampling method has not been adopted as a Federal, State or local standard.
A single direct relationship between asbestos-containing dust and potential human exposure has not been established. Although, a direct relationship between dust levels and exposure has been documented for other contaminants, e.g. lead, this relationship has not been documented for asbestos fibers probably due to the unique aerodynamic aspects of asbestos fibers. Asbestos fibers do not pose a health hazard unless the fibers become airborne and are inhaled.
The ACP has responded to calls from concerned building occupants and reviewed air and bulk sample results received from the building owner. The site visits did not disclose the presence of visible debris within the interior of the building. According to the information in the ACP records, 54 air samples were collected within the building on September 14* 15* and 16* 2001. The samples were analyzed by phase contrast microscopy and were each below O.Olf/cc. Ten bulk samples were collected from exterior surfaces during early July 2002. The results indicated the material was not ACM. On November 1, 2002, 9 additional bulk samples were collected from building exterior surfaces. The results indicated the material was not asbestos-containing material. On March 7, 2003, air samples were collected on the 9* 10* and 11* floors. The samples were analyzed by phase contrast microscopy (PCM) and transmission electron microscopy (TEM). The samples were below the clearance levels. Specifically, the clearance level for PCM samples is 0.01 free and for TEM samples is 70 s/mm^.
Although, the results of several previous site visits and the review of submitted results did not indicate a requirement for further action, the Commissioner requested the building owner to re-clean the carpeting. This re-cleaning and subsequent air testing by DEP would provide employees with a sense of reassurance. The building owner agreed to the request and initiated cleaning of the carpet using wet extraction procedures. These procedures are consistent with activities undertaken at other commercial buildings. The cleaning began on April 1, 2003 and is expected to be completed by April 4, 2003. BEC will perform aggressive air sampling on April 4, 2003. During aggressive air sampling, the air is circulated to simulate activity in the area. The aggressive sampling is the most effective, approved, and accepted method to evaluate potential risk to building occupants. The results will be evaluated using the clearance criteria indicated above.
NYC-WTC_000160134
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160515
Plan outlining cleaning timelines, cancellation policies, HVAC inspection deadlines, and access agreement requirements for February 2003.
8 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156158
Official fax cover sheet from the DEP Commissioner transmitting an attachment regarding environmental compliance issues.
7 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093043
Cover sheet for a fax transmission containing four pages of documents from the Department of Environmental Protection.
7 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
7 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000159829
Coordination memo for WTC recovery inter-agency meeting on building and parks assessment and scope.
6 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
6 shared non-person entities · 1 shared topics · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156145
Response to safety concerns explaining that carpet sonication was conducted and detailing the involvement of health programs.
8 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
5 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156158
Official fax cover sheet from the DEP Commissioner transmitting an attachment regarding environmental compliance issues.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160515
Plan outlining cleaning timelines, cancellation policies, HVAC inspection deadlines, and access agreement requirements for February 2003.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 66 John Street · 2 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Cited alongside this record in an Ask answer
NYC-WTC_000094473
Memo transmitting air sampling results for January 31, 2002, including asbestos data from 86 Trinity Place.
Cited alongside this record in an Ask answer
NYC-WTC_000094486
Letter from Enviroscience Consultants providing air sampling results for the SIAC at 86 Trinity Place.
Cited alongside this record in an Ask answer
NYC-WTC_000094499
Memo reporting air sampling results conducted December 2-3, 2001, at the SIAC and Exchange locations.
Cited alongside this record in an Ask answer
NYC-WTC_000140654
EPA notification of WTC indoor air task force meeting scheduled for April 8, 2002 at 290 Broadway.
Cited alongside this record in an Ask answer