10 shared non-person entities · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗66 JOHN 59 MAIDEN LANE
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000156126–000156144
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
New York City Department of Environmental Protection Asbestos Control Program
66 John Street, Manhattan 9* and 10*^ Floors
Commissioner Ward received information from NYCDEP employees concerned about the results of a carpet sample taken from the 10* floor of 66 John Street. The Commissioner contacted the Bureau of Environmental Compliance (BEC) and the Office of Environmental Health & Safety Compliance (OEHSC). OEHSC then provided the BEC Asbestos Control Program (ACP) with the result of the carpet sonication sample. The sample result was an excerpt of a report which neither ACP, OEHSC nor the Commissioner has received. The sample result indicated a concentration of 393,061 structures/cm^. Carpet sonication is not a New York State Department of Health approved method for the collection and analysis of asbestos-containing or asbestos-contaminated material. Further, this sampling method has not been adopted as a Federal, State or local standard.
A single direct relationship between asbestos-containing dust and potential human exposure has not been established. Although, a direct relationship between dust levels and exposure has been documented for other contaminants, e.g. lead, this relationship has not been documented for asbestos fibers probably due to the unique aerodynamic aspects of asbestos fibers. Asbestos fibers do not pose a health hazard unless the fibers become airborne and are inhaled.
The ACP had responded to calls from concerned building occupants and reviewed air and bulk sample results received from the building owner. ACP then conducted site visits at the building. These site visits did not disclose the presence of visible debris within the interior of the building. According to the information in the ACP records, 54 air samples were collected within the building on September 14‘\ 15*, and 16*, 2001. The samples were analyzed by phase contrast microscopy and were each below 0.01 free. Ten bulk samples were collected from exterior surfaces during early July 2002. The results indicated the material was not ACM. On November 1, 2002, 9 additional bulk samples were collected from building exterior surfaces. The results indicated the material was not asbestos-containing material.
As a result of complaints, the building owner initiated air sampling on March 7, 2003. The air samples were collected on the 9*, 10*, and 11* floors. The samples were analyzed by phase contrast microscopy (PCM) and transmission electron microscopy (TEM). The samples were below the clearance levels. Specifically, the clearance level for PCM samples is 0.01 free and for TEM samples is 70 s/mm^. The ACP asked for and reviewed the data from the air samples after it became aware of complaints regarding the above premises.
Although, the results of several previous site visits and the review of submitted results did not indicate a requirement for further action, the Commissioner requested the building owner to re-clean the carpeting. The building owner agreed to the request and initiated cleaning of the carpet using wet extraction procedures. The cleaning began on April 1,2003 and is expected to be completed by April 4,2003. BEC will perform air sampling on April 4, 2003. The results will be evaluated using the clearance criteria indicated above.
4/3/03
NYC-WTC_000156129
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000155951
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
10 shared non-person entities · Same agency, volume and box · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155920
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
10 shared non-person entities · Same agency, volume and box · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
13 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
14 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
13 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
6 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
7 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
13 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
7 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
11 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117757
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
7 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 2 pages · confidence 0.00 · verify page 3
- 59 Maiden Lane · 1 pages · confidence 0.00 · verify page 17
- 66 John Street · 2 pages · confidence 0.15 · verify page 1
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000156116
Notice instructing staff to preserve original WTC documents collected by the Law Department for potential legal use.
Filed in the same folder
NYC-WTC_000156118
Fax cover sheet from an environmental firm requesting additional samples at 59 Maiden Lane in April 2002.
Filed in the same folder
Filed in the same folder
NYC-WTC_000156123
Fax cover sheet transmitting an EMSL Analytical laboratory report on asbestos testing received March 3, 2003.
Filed in the same folder
Filed in the same folder