NYC-WTC_000139360
DEP official asks if new mold regulations require inclusion in the cleaning scope for 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Document containing New York City Department of Health guidelines for assessing and remediating fungi in buildings.
NYC-WTC_000156098–000156115Folder label: “125 CEDAR 1 OF 2”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
(h) AU areas should be left diy and visibly free from contamination and debris.
3J L^vdTO: Large Isolated Areas (30 -100 square feet) - e.g., several wallboard panels.
A health and safety professional with experience performing microbial investigations should be consulted prior to remediation activities to provide oversight for the project
The following procedures ataminiTnum are recommended: * (a) Persoimel trained in the handling of hazardous materials and equipped with respiratory protection, (e.g., N95 disposable respirator), in accordance with the OSHA respiratory protection standard (29 CFR 1910.134), is recommended. Gloves and eye protection should be worn. (b) The work area and areas directly adjacent should be covered with a plastic sheet(s) and taped before remediation, to contain dust/debris. (c) Seal ventilation ducts/grills in the work area and areas directly adjacent with plastic sheeting. (d) The work area and areas directly adjacent should be unoccupied. Further vacating of people from spaces near the work area is recommended in the presence of infants (less than 12 months old), persons having undergone recent surgery, immune suppressed people, or people with chronic inflammatoiy lung diseases (e.g., asthma, hypersensitivitypne onitis, and severe allergies). (e) Dust suppression methods, such as misting (not soaking) surfaces prior to remediation, are recommended. (f) Contaminated materials that cannot be cleaned should be removed from the building in sealed plastic bags. There are no special requirements for the disposal of moldy materials. (g) The work area and surrounding areas should be HEPA vacuumed and cleaned with a damp cloth and/or mop and a detergent solution. (h) AU areas should be left dry and visibly free from contamination and debris.
If abatement procedures are expected to generate a lot of dust (e.g., abrasive cleaning of contaminated surfaces, demolition ofplaster walls) or the visible concentration ofthe fungi is heavy (blanket coverage as opposed to patchy), then it is reSSShTended that the remediation procedures for Level IV are foUowed.
3.4 Level IV: Extensive Contamination (greater than 100 contiguous square feet in an area)
A health and safety professional with experience performing microbial investigations should be consulted prior to remediation activities to provide oversight for the project. The foUowing procedures are recommended:
9
NYC-WTC_000156110
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000139360
DEP official asks if new mold regulations require inclusion in the cleaning scope for 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144607
Correspondence regarding environmental health risks of spreading elemental mercury contamination through common cleaning equipment in April 1996.
4 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145687
EPA report excerpt discussing the cessation of outdoor air monitoring in June 2002 and ongoing concerns about indoor contamination.
4 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
10 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
8 shared non-person entities · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
8 shared non-person entities · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142730
Guidance document explaining requirements for HVAC cleaning and asbestos abatement regulations for building owners.
6 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142752
Q&A sheet detailing procedures for assessing debris in ventilation systems and required abatement actions.
6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000155793
Notice instructing recipients to preserve original World Trade Center documents as evidence and prohibiting their disposal.
Filed in the same folder
NYC-WTC_000155794
Cover sheet for a fax transmission sent from the US EPA Region 2 office in August 2002.
Filed in the same folder
NYC-WTC_000155800
Cover sheet for a fax transmission sent from the US EPA Region 2 office in August 2002.
Filed in the same folder
NYC-WTC_000155806
Cover sheet for a fax transmission sent from the US EPA Region 2 office to an external recipient in August 2002.
Filed in the same folder
Filed in the same folder