NYC-WTC_000139360
DEP official asks if new mold regulations require inclusion in the cleaning scope for 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Document containing New York City Department of Health guidelines for assessing and remediating fungi in buildings.
NYC-WTC_000156098–000156115Folder label: “125 CEDAR 1 OF 2”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
should be worn. (c) The work area should be unoccupied. Vacating people from spaces adjacent to the work area is not necessary but is recommended in the presence of infants (less than 12 months old), persons recovering from recent surgery, immune suppressed people, or people with chronic inflammatory lung diseases (e.g., asthma, hypersensitivity pneumonitis, and severe allergies). (d) ContarThThTent of die work area is not necessary. Dust suppression methods, such as misting (not soaking) surfaces prior to remediation, are recommended.
(e) Contaminated materials that cannot be cleaned should be removed from the building in a sealed plastic bag. There are no special requirements for the disposal of moldy materials. (f) The work area and areas used by rranedial workers for egress should be cleaned with a damp cloth and/or mop and a detergent solution. (g) All areas should be left dry and visibly free from contamination and debris.
3.2 Level H: Mid-Sized Isolated Areas (10 - 30 sq. ft) - e.g., individual wallboard panels. (a) Remediation can be conducted by regular building maintenance staff. Such persons should receive training on proper clean q? methods, personal protection, and potential health hazards. This training can be performed as part of a program to comply with the requirements ofthe OSHA Hazard Communication Standard (29 CFR 1910.1200). (b) Respiratory protection (e.g., N95 disposable respirator), in accordance with the OSHA respiratory protection standard (29 CFR 1910.134), is re ended. Gioves and eye protection should be worn. (c) The work area should be unoccupied. Vacating people from spaces adjacent to the work area is not necessary but is recommended in the presence of infants (less than 12 months old), persons having undergone recent surgery, immune suppressed people, or people with chronic inflammatory lung diseases (e.g., asthma, hypersensitivity pneumonitis, and severe allergies). (d) The work area should be covered with a plastic sheet(s) and sealed with tape before remediation, to contain dust/debris. (e) Dust suppression methods, such as misting (not soaking) surface prior to remediation, are recommended. (f) Contaminated materials that cannot be cleaned should be removed finm the building in sealed plastic bags. There are no special requirements for the disposal of moldy materials. (g) The work area and areas used by remedial workers for egress should be HEPA vacuumed (a vacuum equipped with a High-Efficiency Particulate Air filter) and cleaned with a damp cloth and/or mop and a detergent solution.
8
NYC-WTC_000156109
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000139360
DEP official asks if new mold regulations require inclusion in the cleaning scope for 125 Cedar Street.
14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144607
Correspondence regarding environmental health risks of spreading elemental mercury contamination through common cleaning equipment in April 1996.
4 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145687
EPA report excerpt discussing the cessation of outdoor air monitoring in June 2002 and ongoing concerns about indoor contamination.
4 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
10 shared non-person entities · 1 shared topics · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
8 shared non-person entities · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
8 shared non-person entities · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142730
Guidance document explaining requirements for HVAC cleaning and asbestos abatement regulations for building owners.
6 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142752
Q&A sheet detailing procedures for assessing debris in ventilation systems and required abatement actions.
6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000155793
Notice instructing recipients to preserve original World Trade Center documents as evidence and prohibiting their disposal.
Filed in the same folder
NYC-WTC_000155794
Cover sheet for a fax transmission sent from the US EPA Region 2 office in August 2002.
Filed in the same folder
NYC-WTC_000155800
Cover sheet for a fax transmission sent from the US EPA Region 2 office in August 2002.
Filed in the same folder
NYC-WTC_000155806
Cover sheet for a fax transmission sent from the US EPA Region 2 office to an external recipient in August 2002.
Filed in the same folder
Filed in the same folder