NYC 9/11 Public Portal Document

December 17, 2002 114 LIBERTY STREET REMOVAL OF DUST, DEBRIS, AND CONTAMINATED MATERIALS

06 TEMPORARY FACILITIES

PART 1 - GENERAL

1.01 DESCRIPTION OF REQUIREMENTS:

A. Provide temporary connection to existing building utilities or provide temporary facilities as required herein or as necessary to carryout the work.

PART 2 - PRODUCTS

2.01 MATERIALS AND EQUIPMENT:

A. Provide new or used materials and equipment that are undamaged and in serviceable condition. Provide only materials and equipment that are recognized as being suitable for the intended use, by compliance with appropriate standards.

2.02 SCAFFOLDING:

A. All scaffolding shall be designed and constructed in accordance with OSHA (29 CFR 1926/ 1910), Municipal Building Code, and any other applicable federal, state, and local government regulations. Whenever there is a conflict or overlap of the above references, the most stringent provisions are applicable. All scaffolding and components shall be capable of supporting without failure of a minimum of 4 times the maximum intended load, plus an allowance for impact. All scaffolding and staging must be certified by a licensed professional engineer.

B. Equip rungs of all metal ladders, etc., with an abrasive, non-slip surface.

C. Provide non-skid surface on all scaffold surfaces subject to foot traffic. Scaffold ends and joints shall be sealed with tape to prevent penetration of contaminated dust.

2.03 WATER SERVICE:

A. Temporary Water Service Connection: All connections to the Owner's water system shall include back flow protection. Valves shall be temperature and pressure rated for operation of the temperature and pressures encountered. After completion of use, connections and fittings shall be removed without damage or alteration to existing water piping and equipment. Leaking or dripping fittings/valves shall be promptly repaired and or replaced as required.

B. Water Hoses: Employ new heavy-duty abrasion-resistant hoses with a pressure rating greater than the maximum pressure of the water distribution system to provide water into each work area and to each Decontamination Enclosure Unit. Provide fittings as required for connection to existing wall hydrants or spouts, as well as temporary water heating equipment, branch piping, showers, shut-off nozzles, and equipment.

26 © AMBIENT GROUP, INC. - 2002

TEMPORARY FACILITIES

NYC-WTC_000155743

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000155743Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →