December 17,2002 114 LIBERTY STREET REMOVAL OF DUST, DEBRIS, AND CONTAMINATED MATERIALS
13 PROJECT DECONTAMINATION
PART 1 - GENERAL
1.01 RELATED DOCUMENTS:
A. Removal of Gross Debris is integral to the performance of abatement work and as such is specified in Section 15 Removal of Contaminated Dust, Debris and Materials.
B. Air testing and other requirements that must be met before release of Contractor and re occupancy of the Work Area are specified in Section 14, Work Area Clearance, and Section 05, Air and Wipe Sampling.
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION
3.01 FIRST CLEANING:
A. After completion of the removal phase, all surfaces from which contaminated materials have been removed shall be scrubbed using nylon or bristle brushes and wet sponges, or cleaned by an equivalent method to remove all visible dust. During this work, the surfaces being cleaned shall be kept damp using an amended water solution. Ail disposable equipment shall be packaged for disposal.
B. All equipment, machinery, scaffolding, tools, etc. within the isolated Work Area shall be wet- wiped and HEPA vacuumed, moved to the equipment room, and properly removed from the Work Area.
C. Prior to the application of any sealant or encapsulating material, and after all visible material has been removed from the substrate. Ambient Group will perform a pre-sealant inspection. The Contractor shall notify Ambient Group, in writing, 24 hours prior to the time the work will be ready for inspection.
D. Following acceptance of first cleaning by Ambient Group, apply a thin coat of pigmented encapsulant to all surfaces in work area where asbestos-containing materials have been removed. Allow a minimum of 4 hours, or as further required by the encapsulant manufacturer, for sealants to dry.
E. Remove the cleaned and encapsulated layer of plastic surface barriers and dispose of as asbestos-containing waste materials.
F. Wait 12 hours to allow negative air machines to clean air of any airborne asbestos fibers.
3.02 SECOND CLEANING:
A. Perform second wet cleaning and HEPA-vacuuming of all surfaces in work area. 53 © AMBIENT GROUP, INC. -2002
PROJECT DECONTAMINATION
NYC-WTC_000155581
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗47 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155168
Draft cleaning procedures and contract documentation for 114 Liberty with minor revisions, shared with EPA for review and comment.
12 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000138892
Forwarding draft cleaning procedures for 114 Liberty Street to EPA for review and comments.
12 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 114 Liberty Street · 16 pages · confidence 0.70 · verify page 79
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer