15 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗114 LIBERTY 1 OF 2
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000155149–000155155
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
DRAFT 4. Sampling equipment shall be placed at representative locations and away from obstruction. Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.
5. The Air Sampling Technician shall perform clearance air sampling after the areas are free of dust accumulations as determined by the Project Monitor. All surfaces must be completely dry prior to the start of sampling. The HVAC systems shall be run for a minimum of 5-6 hours prior to clearance sampling. Clearance air sampling shall be performed at each apartment. Five samples shall be collected in each apartment and two samples shall be collected in each common space. The elevator shaft shall be cleared separately. Clearance air monitoring shall be performed after the completion of all clean up activities at the work site. Clearance air sampling shall be aggressive and performed in accordance with Title 15, Chapter 1 of the RCNY Section 1-43 (a)-(d).
6. Clearance air samples shall be collected in accordance with the procedures specified in the NIOSH 7400 Method. The flow rate for collection of air samples shall be at least 10 liters per minute and no more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If clogging develops, the cassette must be changed.
7. All clearance air samples and completed chain of custody forms must be transported to the laboratory immediately after sampling is completed.
Clearance Criteria
1. The following clearance levels have been established by the USEPA for clean up activities resulting from the collapse of the WTC.
Parameter Clearance Level Note Asbestos in air 0.0009 f/cc PCMe Primary clearance level Lead in settled dust <25 pg/ft" Primary clearance level Dioxin in settled dust <4ng/m^ Primary clearance level Fibrous glass in air <0.01 free Secondary clearance level Crystalline silica in air 0.5(4,g/m'’ Secondary clearance level PAHs in settled dust <0.3 mg/m^ Secondary clearance level Mercury between 1 and 2 mg/m^ Secondary clearance level
2. Cleaning shall not be considered compete unless the primary clearance levels are achieved. The apartment will be re-cleaned and retested if the primary clearance levels are not achieved. These clearance levels may be re-evaluated and revised if determined necessary based on field conditions and analytical limitations. Secondary clearance levels shall be considered in determining the need for additional cleanup, however failure to meet the secondary clearance levels does not automatically trigger the re-cleaning.
4 of 5
NYC-WTC_000155153
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
NYC-WTC_000156050
Document tracking the chain of custody for environmental samples collected at 114 Liberty Street on August 22, 2002.
15 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156019
Document tracking the chain of custody for environmental samples collected at 125 Cedar Street on August 21, 2002.
14 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156000
Contractor work scope for air monitoring and environmental surveillance at 125 Cedar building.
15 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
16 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139389
DEP forwards inspection report for 125 Cedar Street along with NYC guidelines on fungal remediation.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163449
Chain of custody form dated August 22, 2002, documenting transfer of samples or materials between DEP personnel.
15 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗15 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163372
Request to send the air monitoring scope document to legal counsel and the sender due to computer access issues.
14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 114 Liberty Street · 2 pages · confidence 0.15 · verify page 1
- 125 Cedar Street · 1 pages · confidence 0.15 · verify page 7
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000154939
Notice instructing staff to preserve original World Trade Center documents collected from 114 Liberty Street for potential legal use.
Filed in the same folder
NYC-WTC_000154940
EPA confirms that primary and secondary clearance levels for contaminants at 114 Liberty Street have been met.
Filed in the same folder
NYC-WTC_000154944
Summary table of chemical test results including lead and dioxin levels at 114 Liberty Street.
Filed in the same folder
NYC-WTC_000154948
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
Filed in the same folder
NYC-WTC_000154966
Official DEP form notifying authorities of planned asbestos abatement activities at 114 Liberty Street.
Filed in the same folder