NYC 9/11 Public Portal Document
ftPR-16-2003 15=42 LMBORPTORY UNIT P.05z^
1
ASBESTOS ANALYTICAL REPORT
DEP
DIVISION OF EMERGENCY RESPONSE AND TECHNICAL ASSESSMENT
ASBESTOS LABORATORY
96-05 HORACE HARDING EXPRESSWAY
CORONA, NEW YORK 11368
(718) 595-6309 FAX# (718) 595-6307
ELAP # 11045
TEST METHODS : 1) 40 CFR Part 763, Subpart F, App. A
2) Polarized Light Microscopy plus Stratified Point-Counting Method
3) EPA/600/R-93/116
Incident #: TRU0273MN03 Date Collected: 03/27/03
Inspector: R Rammohan Received: 03/27/03
Premise : 114 Liberty Street Analyzed: 03/27/03
Boro : Manhattan
Analyst : G. Roman
Client# :
DEP Sample # : 30327/A078005A
Laboratory #; -3O327Z377A
Location Sampled: On drop ceiling
Color: Light brown
Homogenous; No
Asbestos Present; No
Results • (%) Matrix 88
Fibrous 2
Quartz 10
Comments: this report has results for the brown cementitious material.
Reviewed by:.
Laboratory Director
This test report may not be reproduced except with the written approval of this
laboratory. The teat report relates only to the item(s) listed and does not represent a
product endorsement by NVLAP or any other U.S. Government agency.
TOTPL P.05