z z
o o
CD
'2
o
o ****DRAFT Version 10, October 29, 2001****
■D
c
CT
o'
tn ■D
tAi o
ro IV. Sampling Parameters: 3.
o> 03
Parameter Sample Type Indoor/Outdoor Rationale for Selection
Asbestos breathing ht., VO known use in building construction, evidence of o
o
time-weighted presence in early air sampling and in settled dust, o
c
air known inhalation carcinogen 3
CD
on hold?Total Suspended breathing ht.. O Characterize amount of airborne dust that is
particulates Continuous, real inhalable 100 pm aerodynamic diameter)
time, air
PMlOand PM2.5 breathing ht.. O Characterize the amount of airborne dust that is
Continuous, real respirable
time, air
Inhalable (< 100pm)* breathing ht., I/O To determine relative amounts of each fraction present
thoracic (<10pm)* time-weighted, and to have each fraction analyzed for silica, gypsum,
respirable (<2.5pm)* air mica, fiberglass, and calcite to qualitatively determine potential
hazards.
Respirable breathing ht., VO Known component of concrete, evidence of
crystalline silica time-weighted, presence in some settled dust samples, known
air inhalation carcinogen.
pH** dust VO Concrete has a high pH, if dust has a high pH, it may be
contributing to reported symptoms of ENT irritation
Asbestos** dust VO Determine if asbestos is present in dust
gypsum,silica, mica, dust VO Associated with building materials (concrete,
fiberglass, calcite** drywall) and known to be irritating to ENT
magnesium dust VO May act as a tracer for WTC-related dust, levels found in
metals analysis of settled dust from 16,000-29,000 ppm
* results will be used to better understand the potential for ENT and respiratory irritation, and possibly for determining the possibility of acute/chronic health
problems. Results will assist in providing information/recommendations to the public (e.g., what is contributing to irritation, how to reduce exposures)
** to assist in characterizing dust that can become airborne (re-entrainment of settled dust that may be the source of continuing air contamination), and
to make recommendations for outdoor dust remediation
Page 4 of