At least two field blanks (or 10% of samples submitted, whichever is greater) per sample location
will be submitted with the air samples. Blank cassettes should be opened at the same time as the
sample cassettes are opened (just prior to sampling). Blank cassettes and their covers should be
stored in a clean area (e.g., closed bag or box) with the covers from the sampling cassettes during
the sampling period.
Each air sampling pump will be calibrated with a representative sampling device in-line before
and after sample collection. Sample flow rates will be documented in the sampling log. The
average of pre- and post-calibration flow rates will be used as the sample flow rate, for sample
volume calculations.
Dust samples will be collected using the EPA Environmental Response Team (ERT) indoor dust
sampling standard operating procedure (SOP). Duplicate samples are not feasible with indoor
surface dust sample collection. Co-located samples (samples collected from adjacent areas of the
floor) will be collected in 10% of the indoor surface dust sample locations. While not a true
duplicate, evaluation of the results will provide some information on the variability of
contaminants in the dust.
Samples should not be packaged in untreated polystyrene-electrostatic forces may cause fiber
loss from some sample filters.
Chain of custody will be established and maintained throughout sample collection, transport, and
analysis of the samples. Laboratory analysis shall follow all method-required quality assurance
and quality control procedures.
All samples collected, unless analyzed with destructive methods, will be archived until further
notice.