DRAFT Test C (Carpet Shampooing) Wall to wall carpeting in both Units will be shampooed or steam cleaned using commercial duty equipment.

Scenarios 1,2 and 3 will be each be tested on four units. Scenario 4 will be tested on the 2 commercial spaces. Additional evaluation of wet wiping methods will be conducted on the 15* ( Dwelling) that has been not proposed for evaluation under the previously proposed scenarios. Samples will be collected prior to, during and after cleanup in accordance with the SAP to determine the effectiveness of the cleaning. If sample results do not attain cleanup objectives for a specific scenario, the unit will be re-cleaned using the same equipment and re-sampled. If after a second cleaning the results are unsatisfactory the unit will be cleaned using a method proven successful.

6) Disposal of cleanup generated waste:

Dust/debris, used protective equipment, clogged vacuum filters, expendables and items discarded by the tenant will be double bagged in 6ml plastic bags and deposited in a roll off container placed out side the building. The roll off container will be transported off site when full and replaced with another roll-off container. Water used for hand washing and equipment washing will be disposed into the sanitary sewer.

4. PROJECT SAMPLING;

USEPA will perform comprehensive sampling before, during and after the cleanup to evaluate the effectiveness of the work and possible worker exposure. Samples of dust collected by wipe, micro vac, and personnel pump sampling techniques will be obtained from porous and nonporous surfaces as well as from workers. Prior to the start of work, bulk samples will be collected (if possible) from each unit. If bulk samples cannot be collected, samples will be obtained using wipe or micro - vac techniques. Samples will be collected from the locations, and analyzed for the parameters shown on the tables included as Attachment B. Specific sampling protocols, methods as well as sample management, data validation and reporting are detailed in the SAP.

5. REPORT PREPARATION;

Upon completion of the study a summary report will be prepared discussing the work performed under each scenario. The report will present a synopsis of the work, detailing conditions of the units prior to and after the cleanup, duration of the cleanup, problems encountered during the cleanup, sample locations, laboratoiy data summary tables, and QA/QC documentation. This information will be presented to USEPA for evaluation and recommendation.

NYC-WTC_000149906

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149906Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →