NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/ATSDR/DHAC_ASTM
Document / 146 pages

Chain of Custody Form Instructions for WTC Building Sampling

Machine-extracted title · confidence 100%

Instructions and sections for collecting sample location data from a specific building interior.

NYC-WTC_000149537–000149682

Folder label: “ATSDR/DHAC_ASTM

Page image
Scanned page image, NYC-WTC_000149562
OCR text

OCR status: ok · source: pdftotext

z

J • Compare results to representative background.** • Compare results to representative background.** o co

s 155 • Identify meteorological conditions and factors such as 0 Review pre-sampling questionnaire responses. ■D c CT road traffic during sampling. • Evaluate multiple source contributions (WTC, o' • Use for evaluation of outdoor contribution to indoor outdoor, indoor activities cooking cleaning,..). "□ o concentrations 0 Assess ventilation systems (heating and cooling). 9L • Compare to DEC monitors 0 Recommend proper clean-up techniques be employed. O o 0 Consider re-sampling and evaluate nearby o c residences/common areas. 3 CD 3

Inhalable Particulate 24 hour TSP 2

• Compare results to representative background.** • Compare results to representative background.** 250 • Identify meteorologic conditions, activities such as > Assess ventilation systems (heating and cooling). road traffic or construction activities during sampling. 0 Consider evaluating with modification to occupational • Assess the need for dust suppression procedures. standards. ® • Recommend proper clean-up techniques be employed. 0 Consider re-sampling after clean-up has occurred.

** As sampled in “Ambient and Indoor Sampling for Public Health Evaluations of Residential Areas Near WTC.” National Ambient Air Quality Standard (NAAQS) Total Suspended Particulates, New York State Ambient Air Quality Standard ’ The range of ratios reported in the 1996 and 2001 draft Ambient Air Criteria Documents for Indoor and Outdoor concentrations rf PM 2.5 could be used to select a multiplier to be applied to the area level of concern. While estimates (from a limited number of studies) range from slightlyless than one, to two (higher if smoking

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149562Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

24 shared non-person entities · Same agency, volume and box · similarity 0.975

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →