NYC 9/11 Public Portal Document
Asbestos/MMVF f'cc % by weight
Metals' & Mercury ugZm^ ug/m^ ug/m’ mg/kg
Silica, calcite, gypsum N/A mg/m^ mg/m’ % by weight
' Report lead as both ug/m^ and ug/fF.
6) Due to the sensitive nature of this project, all data is to be reported on time. Should data be
received beyond the due date the laboratory shall assume the appropriate late charges as agreed
between the Contracting Officer and Region 2.
7) Data turnaround times shall be as follows.
Analyte Code Analysis Fields Collection Method Data
Background and Residential Turnaround
Asbestos* NIOSH7400PCM>5um Mico vacuum-ASTM D 24 hours
5755-95, wipe-ATSM D
PCMe by TEM asbestos only > 5 um 6480-99, air-NIOSH 7400, Standard (3 days)
and bulk
TEM by AHERA > 0.5 um
Dioxins EPA Method SW-846 8290 Wipe ASTM D 6661-01 and 14 days
bulk
Total Dust EPA Method SW-846 8290 Wipe HUD Appendix 13.1 14 days
PAH EPA Method SW-846 8270C Wipe ASTM D 6661-01, 14 days
bulk
Metals EPA Method SW-846 601 OB Micro-Vacuum ASTM E 14 days
1973-99, Wipe HUD
Appendix 13.1, Air NIOSH
7300, and bulk
Mercury EPA Method SW-846 7471A Wipe HUD Appendix 13.1, 14 days
Silica, Calcite, NIOSH 7500 (XRD) Wipe HUD Appendix 13.1, 21 days
Gypsum Air NIOSH 7500, and bulk
MMVF EMSLMSD.0300 Collected with asbestos, 14 days
Micro-Vacuum ASTM D
5755-95, Wipe ATSMD
6480-99, NIOSH 7400
MMVF PLMNYS 198.1/EMSL MSD.0300 Collected with asbestos. 14 days
Bulk
*PCM NIOSH 7400, TEM by AHERA method reporting both TEM and PCMe. Samples are collected using a 0.8 um
filter pore size.
NYC-WTC_000149370