NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/NO INFO
Document / 246 pages

VOC sampling locations table for Ground Zero area, Jan 2002

Machine-extracted title · confidence 100%

Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.

NYC-WTC_000148952–000149197

Folder label: “NO INFO

Page image
Scanned page image, NYC-WTC_000149027
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 4. Measured dioxin TEQ air concentrations at the WTC Building 5 monitor, the Church & Dey monitor, and the Park Row monitor (all units = pg TEQ/m^; NR = not reported; all TEQ calculated at ND = DL except values in parenthesis, which are calculated at ND = 0).

Date WTC-Building 5 Date Church & Dey Date Park Row 9/23 161,0(161.0) 9/23 139.0(139.0) 10/12’ 8.35 9/27 NR 9/27 50.0 (NR) 10/14“ 0.34 10/2 175.0 (170.0) 10/2 59.3 (57.2) 10/15“ 4.78 10/4 176.0(140.0) 10/4 51.9 (50.6) 10/16“ 7.55 10/8 32.0 (28.7) 10/8 17.7 (15.5) 10/26 6.51 10/11 52.4 (9.6) 10/11 15.6(11.8) 10/29 6.34 10/18 NR 10/18 9.6 (8.8) 11/1 3.05 10/26 28.1 (24.9) 10/26 11.4(10.2) 11/5 1.54 11/2 26.8 (25.4) 11/2 16.1 (15.1) 11/8 0.27 11/6 0.3 (0) 11/6 0.1 (0) 11/12 1.33 11/8 5.6 (4.9) 11/8 7.6 (7.1) 11/15 1.33 11/12 NR 11/12 1.3 (0.6) 11/19 2.50 11/15'’ 5.4 (1.6) 11/15 3.4 (1.6) 11/22 1.30 11/21'’ 4.1 (3.1) 11/21 10.0 (8.3) 11/26 0.80 No samples reported from 11/21 11/27 2.5 (NR) 11/29 0.16 to 1/15 12/4 0.7 (NR) 12/3 0.12 Jan 15-April 24 12/6 0.2 (NR) 12/6 0.04 n = 31 reported range: 0.4-5.5 12/11 0.2 (NR) 12/10 0.05 average: 1.4 at ND = 'A DL and 0.0 at ND = 0. 12/19 0.6 (NR) 12/13 0.04

12/27 0.3 (NR) 12/24 0.04 Jan 3 - April 24 12/27 0.06 n = 29 reported range: 0.2 - 4.1 12/31 0.11 average: 1.4 at ND = DL and 0.0 at ND = 0. Jan - Feb n=17 all samples reported < = 0.05

“ These Park Row samples were 24-hour samples; all other Park Row samples were 72 hour samples. '* These two World Trade Center samples were actually taken at the Church & Vesey sampler, which was sometimes used in place of the WTC Building 5 sampler.

DRAFT-DO NOT QUOTE OR CITE 83 October 2002

NYC-WTC_000149027

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149027Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

35 shared non-person entities · Same agency, volume and box · similarity 0.960

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →