NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/DEP Box 08/INTERIM FINAL April 2003
Document / 161 pages

EPA interim final report on WTC background study, April 2003

Machine-extracted title · confidence 100%

Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.

NYC-WTC_000145869–000146029

Folder label: “INTERIM FINAL April 2003”

Page image
Scanned page image, NYC-WTC_000145951
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 7-2. Summary of Settled Asbestos Surface Dust Loadings Determined Through Microvacuum Sampling and Indirect Analysis by Transmission Electron Microscopy

Building Number of Number of Surface Loading of Asbestos Structures Category Buildings Samples (s/cm^) Range Geometric Mean Outside buildings 5 79 <400 to 140,000 5100 in a large city Inside buildings 6 28 <240 to 210,000 1000 with no surfacing ACM Areas of 12 34 <3500 to 74 million 160,000 buildings with acoustical plaster

Source: Ewing (2000).

ACM = asbestos-containing material

NYC-WTC_000145951

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145951Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Cited alongside this record in an Ask answer

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Cited alongside this record in an Ask answer

Compare copies and versions →