Reference Concentration (RfC) or IRIS Slope Factor exists, there are methodologies for examining risks of non-occupational exposures, on which to draw upon for a risk based approach to set benchmark levels. The approach taken here is a dual approach, where in the face of uncertainties the quantification of the benchmarks was based on the current occupational standards. Broader risk-based discussion of other methodologies provides support for the chosen benchmark levels although not quantitatively employed here to derive the benchmarks.

The Tier I benchmark is set at one tenth of the OSHA PEL. A single year of exposure at this benchmark (lOug/m’) would provide a cumulative silica loading to the lungs less than the Img/m’ work-year loading which is believed to be the departure point for adverse health effects. Additionally this level is also the effective National Ambient Air Quality Standard for silica, where PMiq at 50 ug/m^ contains no more than 10% crystalline silica. A recent review by supports the finding that this level would be protective of long-term non-cancer health effects [EPA, 1996]. The Tier IH benchmark is set at one hundredth of the OSHA PEL. A 30 year continuous exposure at this level would not result in a cumulative silica loading to the lungs greater than the Img/m’ year loading which is believed to be the departure point for adverse health effects.

26

NYC-WTC_000145983

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145983Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132498 · Box DEP Box 54

A DEP report describing ambient outdoor air monitoring for asbestos in Lower Manhattan following the World Trade Center disaster.

Cited alongside this record in an Ask answer

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

NYC-WTC_000142802 · Box DEP Box 06

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

Cited alongside this record in an Ask answer

Compare copies and versions →