Appendix K

Indoor Air and Dust Test Results EPA conducted indoor air monitoring and indoor dust wipe sampling in the weeks after the collapse. This EPA indoor air monitoring (prior to the FEMA-funded residential cleanup) was limited primarily to testing for asbestos in buildings. EPA’s dust wipe sampling tested for metals, PCBs, and dioxin.

On September 13, 2001, 14 air samples were collected from 26 Federal Plaza, 290 Broadway, and Chase Manhattan Plaza, and analyzed for asbestos. All samples were analyzed by TEM and the results converted to PCM equivalent readings in fibers per cubic centimeter (free). One of the 14 samples exceeded the New York City standard for asbestos clearance of .01 free (see Table K-1). Table K-1; Indoor Air Test Results from September 13,2001 PCM Analysis TEM Analysis

_______ Address Sample Volume _I1L_ WO y 8/mm2 S-.5.5 PI Sil [41 Chase Manhattan Plaza 571 np na na 0.0098 na na na 26 Federal Plaza (13th floor) 16370 np na na 0.0064 na na na 26 Federal Plaza (13th floor) 16371 np na na <0.0033 na na na 26 Federal Plaza (Lobby S.) 16372 np na na 0.0072 na na na 26 Federal Plaza (Lobby W.) 16373 np na na 0.0037 na na na 26 Federal Plaza (39*’ floor) 16374 np na na <0.0038 na na na 26 Federal Plaza (38”’ floor) 16375 np na na <0.0039 na na na 26 Federal Plaza (26”’ floor) 16376 np na na <0.0038 na na na 290 Broadway (8*” floor) 27490 np na na 0.0042 na na na 290 Broadway (Lobby) 27491 np na na <0.0043 na na na 290 Broadway (22"” floor N.) 27492 np na na <0.0041 na na na 290 Broadway (22"” floor S.) 27493 np na na 0.004 na na na 290 Broadway (LL-1) 27494 np na na 0.013 na na na 290 Broadway (LL-2) 27495 np na na 0.0044 na na na

KEY: np = sample volume not provided on data sheets. na= not analyzed for this metric.

NOTES; [1] = sample volume for TEM (AH ERA method) is 1200 liters for 25 mm filter [2] = fibers per millimeter squared [3] = structures equal to or greater than 0.5 micrometers and less than or equal to 5 micrometers in length [4] = structures greater than 5 micrometers in length

During the period September 17 to November 3,2001, EPA collected dust wipe samples within four buildings: Stuyvesant High School, Public School 234, Manhattan Borough Community College, and the Jacob Javits Convention Center. The samples were analyzed for various metals at all locations, while at Stuyvesant and the Community College samples were also collected and analyzed for PCBs and dioxin. Fifty-four percent of the sample results were below the minimum

93 Report No. 2003-P-00012

NYC-WTC_000145448

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145448Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →