NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 05/B.Avaltroni EPA INDOOR AIR TASK FORCE
Document / 1 page

Asbestos fiber evaluation criteria and resampling requirements, April 2002

Machine-extracted title · confidence 100%

Criteria for determining necessary actions when asbestos levels exceed background, including resampling and ongoing cleaning protocols.

NYC-WTC_000140825

Folder label: “B.Avaltroni EPA INDOOR AIR TASK FORCE

Page image
Scanned page image, NYC-WTC_000140825
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Air level: Evaluate conditions in the area For those areas where air levels would NYC background including representativeness of air not warrant removal of sensitive - 0.01 fZee * samples, fibrous glass dust levels individuals, but are above the 0.001 and loading. fee, continued cleaning and Or evaluation is prudent.

Settled Dust level: If air samples were not taken, then Settled dust threshold is to protect to appropriate air sampling should be at least a IXIO"^ risk estimate for a 30 10,000 fem^ conducted to determine if fiber year exposure. Air concentrations To levels are elevated. estimated for different activities using 100,000 fem^ a K factors based on Millette’s work Take actions to reduce exposures. on asbestos. Risk estimate is based on - clean area estimates of air levels, and duration of - resample exposure for different activities. - ongoing cleaning (10,000fcm2 corresponds to a 1x10-4 risk for a 30 year exposure)

NYC-WTC_000140825

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140825Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000140812 · Box DEP Box 05

Notice instructing staff to preserve original WTC documents as potential evidence in future legal actions against the City.

Filed in the same folder

Compare copies and versions →