removal of debris, all surfaces shall be HEPA vacuumed and wet wiped. Encapsulating
agents shall not be applied. Once all surfaces have been HEPA vacuumed and wet wiped, a
second cleaning shall be performed. Surfaces include but are not limited to walls, floors,
ceilings, ledges, trims and furnishings.
11. Surfaces that may not be wiped shall be HEPA vacuumed three times or disposed as ACM
waste. Disposal of residents personal property may not occur without prior authorization by
USEPA and the owner.
12. A cleaning checklist (to be developed) will be completed by the supervisor at thee
completion of the cleaning.
13. A thorough visual inspection will be conducted by the Project Monitor to verify the absence
of visible dust accumulations. Additional clean-up procedures shall be performed where
visible dust is observed.
14. After successful clearance air monitoring isolation barriers shall be removed in conjunction
with the use of a HEPA vacuum.
15. Air sampling shall be performed by the Monitoring Contractor after the area is free of dust
accumulations as determined by the Project Monitor. If the apartment does not meet the
cleanup criteria of 0.0009 fibers/cc(TEM), the apartment will be recleaned at no additional
cost and retested, [additional analytical language required]
16. Any damage or loss to that occurs during cleaning is the responsibility of the cleaning
contractor. The cleaning contractor is not responsible for damage or loss caused by the acts
of parties not involved in the cleanup.
17. AU work shall be in compliance with all other applicable requirements of Title 15, Chapter
1 of the Rules of the City of New York and New York Industrial Code Rule 56.
Transportation and disposal of generated waste shall be in compliance with all applicable
rules and regulations.