NYC 9/11 Public Portal Document
»
.1
Even if the air was tested using large volumes of air in order to increase the sensitivity, compared
to the AHERA TEM clearance test, it may not be practical. This is because of the long time
required (8 hours for a 48(X) liter sample) hours, and the expense (around $400 for the lab fee if
32 “grids” of the filter are read by the analyst). There would need to be people present during the
8 hours not only to insure that no one sabotaged the test by cutting the pump off or spread
asbestos during pumping, but also because the test would need to represent air conditions during
normal human activities. If the air was tested with no people present, the results would be
unrealistically low, since normal human activities stir up asbestos and cause it to become
airbome.
The ultrasonication method is not likely to result in an over-count of asbestos fibers due to the
separation of bundles of fibers during the sonication procedure. This is particularly true for
WTC fallout, which is already finely divided.^ High impacts, such as foot traffic or children
playing with toys on carpets, would certainly result in the breakdown of asbestos fibers that are
bundled together into individual asbestos, resulting in an increase in the number of fibers, and
also an increase in the hazard.
Finding a iab and submitting samples
First, locate a laboratory who will perform ultrasonication tests of carpet, upholstery, and
draperies. There is a list of accredited asbestos laboratories maintained by the National Institute
for Standards and Technology (NIST) on the internet, or call the NIST at the number in the
reference section.’
Then call the lab and ask if they can perform “EPA’s ultrasonication extraction asbestos method
for carpet, the Millette method.”^ Use this phrase to describe the test when talking to the lab.
The EPA method number is EPA-600/J-93/167, but most lab receptionists will not recognize the
method by just this number. Because this is a less common method, you may need to speak to
the lab director.
Ask which particular one of their labs does this test, and where to send the sample. This test is
usually done at only one of their lab locations. Ask the lab for instructions for sending the
sample. Labs will refuse your samples if you do not follow their instructions exactly. Carpet
and fabric samples should be enclosed in double Ziplock® sealed baggies.
Laboratories will require that you fill out their Chain of Custody form. Often you can download
the chain of custody form from their web site, or they will fax it to you. You must indicate on
-4-
NYC-WTC_000140088
OCR can misread numbers and units. Confirm readings against the page image before using them.