NYC 9/11 Public Portal Document
49. US EPA, Title 40 of the Code of Federal Regulations, Part 761.61 — PCB remediation
waste. Posted at: http://www.epa.gov/epahome/cfr40.htm
For non-porous surfaces in high occupancy areas, the level of polychlorinated dibenzodioxins
must be less than or equal to 10 micrograms per 100 centimeters squared (s 10 pg/lOO cm 2).
US EPA, Title 40 of the Code of Federal Regulations, Part 745.227 — Lead dust. Posted at:
http://www.epa.gov/epahome/cfr40.htm
A lead-dust hazard on interior surfaces is an average level of lead in dust that equals or exceed
50 (jg/ft2 [micrograms per square foot] on uncarpeted floors and 250 pg/ft2 on interior window sills
50. Gonzales, J. (March 21, 20(G) A Red Flag on Air Tests at WTC, NY Daily News.
51. Mugdan, Walter E. (January 25,2002), op. cit.
52. EPA website on September 11 Response. See page posted at
http://www.epa.gov/epahome/wtc/activities.htm and every individual data page linked to the
map of bulk dust sampling at http://www.epa. gov/envito/nyc/bulkdust/
53. Jenkins, C. (April 30,2002, with May 7 update) TEM vs. PLM METHODS FOR
ASBESTOS DUSTS: TEM found over 1% asbestos, but PLM tests showed NONE; EPA PLM
tests of WTC fallout dust may have imderestimated area of asbestos contamination; EPA Region
2 knew TEM was required and needed, had it after the WTC collapse for their own building,
used it in past, but refused to use it for the rest of NYC. Memorandum addressed to Affected
Parties and Responsible Officials from Cate Jenkins, Hazardous Waste Identification Division,
OSW, EPA. Posted at www.NYenviroLAW.org.
The New York Environmental Law and Justice Project, as well as the New York City
Department of Environmental Protection and the US EPA Region 2 tested dust from the
roof and in an open elevator shaft of an apartment at 150 Franklin St. in April, 2002.
Testing by PLM showed no asbestos. But when the exact same samples were retested
using transmission electron microscopy (TEM), the dust had asbestos over 1%, and in one
case at a level of 5%. Franklin St. is about 2 blocks north of the Hudson St. apartment
building.
54. Carlton, J. (May 9,2(M)2) Bureaucratic Buck-Passing Delayed Asbestos Cleanup After 9/11
Attacks. Wall Street Journal, www.wallstreetjoumal.com Also posted at
www.NYenviroLAW.org
But Ms. Jenkins and other critics of her agency's performance have said that one of the EPA's
failings was its unwillingness to urge New York to use the most-up-to-date method of asbestos
testing — a method employing electron microscopes that the EPA has used elsewhere. The city
instead advised building owners to use only an older technique, in which testers search for
contaminants using polarizedlight microscopes that work much like ones used in high-school
chemistry labs. Electron microscopes, used with computers, can detect asbestos fibers that light
-38-
NYC-WTC_000140078
OCR can misread numbers and units. Confirm readings against the page image before using them.