Table B - ASBESTOS AIR CONCENTRATIONS AND RISKS
Excess Cancer Air Level - Air standards, levels actually found, detection limits, etc.
Risks, Lifetime fibers per
Exposure milliliter, PCM YOU MUST CONVERT STRUCTURES PER MILLILITER TO "PCM-EQUIVALENT"
(70 years)*’ equivalent FIBERS PER MILLILITER BEFORE USING THIS CHART. Unless you hove actual
f/mL (PCM) data, divide s/mL by around 2 to 4 to convert to "f/mL PCM"
1 per 100 0.04 EPA's Integrated Risk Information System (IRIS) cancer risk level
0.0095 - 0.019 AHERA level of 70 structures per square millimeter, converted to PCM-
equivalent fibers per milliliter. Over 2 cancers per 1000.
1 per 1,000 0.004 EPA's Integrated Risk Information System (IRIS) cancer risk level
0.0011 - 0.0043 Region 2*5 detection limits, converted to PCM equivalents (25 to 50% of fibers
estimated to be PCM equivalent). THE LOWEST LEVEL THEY COULD HND. Up
to 2 cancers per 1000.
0.0024 Libby Superfund site, average inside homes resulting In Superfund
designation. Approaching 1 cancer per 1000.
1 per 10,000 0.0004 EPA's integrated Risk Information System (IRIS) cancer risk level**
1 per 100,000 0.00004 EPA's Integrated Risk Information System (I US) cancer risk level
1 per 1,000,000 0.000004 EPA's Integrated Risk Information System (IMS) cancer risk level.
0.000003 inside air. Agency for Toxic Substances and Disease Registry, peer reviewed
overall value. Less than 1 cancer per 1 million.
0.000002 outside air. Agency for Toxic Substances and Disease Registry, peer reviewed
overall value. Less than 1 cancer per 1 million.
0 cancers 0 AHERA safe level standard, 40 CFR $763, Appendix C - Asbestos Model
Accreditation Plan
0 Asbestos Scheel Hazard Detection and Qmtrol Act safe level