Environmental Protection Agency n. 763, Subpt E, App. A
8, Perform a systems check on the trans tron Microscopy Using Polycarbonate Mem
mission electron microscope dally. brane Filters.” WERL SOP 87-L March 5,
9. Make periodic performance checks of 1987.
magnification, electron diffraction and en 9. NIOSH. Method 7402 for Asbestos Fibers,
ergy dispersive X-ray systems as set forth in December 11, 1986 Draft,
Table III of Unit III.K. 10. Yamate, G,, S,C, Agarwall, R,D, Gib
10. Ensure qualified operator performance bons, IIT Research Institute, “Methodology
by evaluation of replicate counting, dupli for the Measurement of Airborne Asbestos by
cate analysis, and standard sample compari Electron Microscopy,” Draft report, USEPA
sons as set forth in Table III of Unit III.K. Contract 68-02-3266, July 1984,
11. Validate all data entries. 11, Guidance to the Preparation of Quality
12. Recalculate a percentage of all com /Assurance Project Plans, USEPA, Office of
putations and automatic data reduction Pollution Prevention and Toxics, 1984.
steps as specified in Table III. ZV. Mandatoiy Interpretation of Transmission
13. Record an electron diffraction pattern Electron Microsct^ Results to Determine
of one asbestos structure from every five Completion ofResponse Actions
samples that contain asbestos. Verify the
Identification of the pattern by measure A. Introduction
ment or comparison of the pattern with pat
terns collected from standards under the A response action is determined to be com
same conditions. pleted by TEM when the abatement area has
been cleaned and the airborne asbestos con
The outline of quality control procedures centration Inside the abatement area is no
presented above is viewed as the minimum higher than concentrations at locations out
required to assure that quality data Is pro side the abatement area. “Outside” means
duced for clearance testing of an asbestos outside the abatement area, but not nec
abated area. Additional information may be essarily outside the building, EPA reasons
gained by other control tests. Specifics on that an asbestos removal contractor cannot
those control procedures and options avail be expected to clean an abatement area to an
able for environmental testing can be ob airborne asbestos concentration that is
tained by consulting References 6. 7. and 11 lower than the concentration of air entering
of Unit III.L. the abatement area from outdoors or from
L. References other parts of the building. After the abate
ment area has passed a thorough visual In
For additional background information on spection, and before the outer containment
this method the following references should barrier Is removed, a minimum of five air
be consulted. samples inside the abatement area and a
1. "Guidelines for Controlling Asbestos- minimum of five air samples outside the
Containing Materials in Buildings,” EPA 560/ abatement area must be collected. Hence,
5-85-024, June 1985, the response action is determined to be com
2. “Measuring Airborne Asbestos Following pleted when the average airborne asbestos
an Abatement Action,” USEP/Office of Pol concentration measured inside the abate
lution Prevention and Toxics, EPA 600/4-85- ment area is not statistically different from
049, 1985. the average airborne asbestos concentration
3. Small. John and E. Steel. Asbestos measured outside the abatement area.
Standards: Materials and Analytical Meth The inside and outside concentrations sire
ods. N.B.S. Special Publication 619, 1982, compared by the Z-test, a statistical test
4. Campbell, W.J„ R,L, Blake, L.L. Brown, that takes Into account the variability In
E.E, Cather, and J,J, Sjoberg. Selected Sili the measurement process. A minimum of
cate Minerals and Their Asbestlform Vari five samples Inside the abatement area and
eties. Information Circular 8751, U,S, Bureau five samples outside the abatement area are
of Mines, 1977. required to control the false negative error
5. Quality Assurance Handbook for Air Pol rate, i,e., the probability of declaring the re
lution Measurement System. Ambient Air moval complete when, in fact, the air con
Methods, EPA 600/4-77-027a, USEPA, Office of centration inside the abatement area is sig
Research and Development, 1977, nificantly higher than outside the abatement
6. Method 2A: Direct Measurement of Gas area. Additional quality control is provided
Volume Through Pipes and Small Ducts, 40 by requiring three blanks (filters through
CFR Part 60 Appendix A. which no air has been drawn) to be analyzed
7. Burdette, G,J. Health & Safety Exec,, to check for unusually high filter contami
Research & Lab. Services Div., London, nation that would distort the test results.
“Proposed Analytical Method for Determina When volumes greater than or equal to
tion of Asbestos in Air,” 1,199 L for a 25 mm filter and 2,799 L for a 37
8, Chatfield, E,J,, Chatfield Tech, Cons., mm filter have been collected and the aver
Ltd,, Clark, T,, PEI Assoc. ‘’Standard Oper age number of asbestos structures on sam
ating Procedure for Determination of Air ples inside the abatement area is no greater
borne Asbestos Fibers by Transmission Elec than 70 s/mm^ of filter, the response action
703