NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 03/2002 E-Mail Sent M. Gilsenan
Document / 74 pages

Forwarding WTC air monitoring scope for final review, Aug 2002

Machine-extracted title · confidence 95%

DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.

NYC-WTC_000139257–000139330

Folder label: “2002 E-Mail Sent M. Gilsenan

Page image
Scanned page image, NYC-WTC_000139274
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Protection Agency §763.92 (c) Cleaning—(I) Initial cleaning. Un­ small-scale, short-duration mainte­ less the building has been cleaned nance activities, shall be designed by using equivalent methods within the persons accredited to design response previous 6 months, all areas of a school actions and conducted by persons ac­ building where friable ACBM, damaged credited to conduct response actions. or significantly damaged thermal sys­ (f) Fiber release episodes—W Minor tem Insulation ACM, or friable sus­ fiber release episode. The local education pected ACBM assumed to be ACM are agency shall ensure that the proce­ present shall be cleaned at least once dures described below are followed in after the completion of the Inspection the event of a minor fiber release epi­ required by §763.85(a) eind before the sode (i.e., the falling or dislodging of 3 Initiation of any response action, other square or linear feet or less of friable than O&M activities or repair, accord­ ACBM): 5 ing to the following procedures: (1) Thoroughly saturate the debris (I) HEPA-vacuum or steam-clean all using wet methods. carpets, (ii) Clean the area, as described in (11) HEPA-vacuum or wet-clean all paragraph (e) of this section. other floors and all other horizontal (ill) Place the asbestos debris in a surfaces, sealed, leak-tight container. (111) Dispose of all debris, filters, (iv) Repair the area of damaged ACM mopheads, and cloths In sealed, leak- with materials such as asbestos-free tight containers, spackling, plaster, cement, or insula­ (2) Additional cleaning. The accredited tion. or seal with latex paint or an management planner shall make a encapsulant. or immediately have the written recommendation to the local appropriate response action Imple­ education agency whether additional mented as required by §763.90. cleaning is needed, and if so, the meth­ (2) Major fiber release episode. The ods tind frequency of such deeming. local education agency shall ensure (d) Operations and maintenance activi­ that the procedures described below are ties. The local education agency shall followed in the event of a major fiber ensure that the procedures described release episode (I.e.. the falling or dis­ below to protect building occupants lodging of more than 3 square or linear shall be followed for any operations feet of friable ACBM): and maintenance activities disturbing (i) Restrict entry into the area and friable ACBM; post signs to prevent entry into the (1) Restrict entry into the area by area by persons other than those nec­ persons other than those necessary to essary to perform the response action. perform the maintenance project, ei­ (11) Shut off or temporarily modify ther by physically isolating the area or the air-handling system to prevent the by scheduling, distribution of fibers to other areas in (2) Post signs to prevent entry by un­ the building. authorized persons, (ill) The response action for any (3) Shut off or temporarily modify major fiber release episode must be de­ the air-handling system and restrict signed by persons accredited to design other sources of air movement. response actions and conducted by per­ (4) Use work practices or other con­ sons accredited to conduct response ac­ trols, such as, wet methods, protective tions. clothing, HEPA-vacuums, mini-enclo­ sures, glove bags, as necessary to in­ §763.92 Training and periodic surveil­ hibit the spread of any released fibers, lance. (5) Clean all fixtures or other compo­ (a) Training. (1) The local education nents in the immediate work area, agency shall ensure, prior to the imple­ (6) Place the asbestos debris and mentation of the O&M provisions of other cleaning materials In a sealed, the management plan, that all mem­ leak-tight container. bers of its maintenance eind custodial (e) Maintenance activities other than staff (custodians, electricians, heating/ small-scale, short-duration. The response air conditioning engineers, plumbers. action for any maintenance activities etc.) who may work in a building that disturbing friable ACBM, other than contains ACBM receive awareness

659

NYC-WTC_000139274

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000139274Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →