above, 5 air samples shall be collected. Sampling equipment shall be placed in living areas
and away from obstructions. The sampling cassette must be placed on a tripod, not taped
to existing surface and should be directed downward at a 45 degree angle.
d. Common spaces will be sampled without the use offorced air devices (fans, leafblowers
etc). For small spaces, less than 160 square feet, 3 samples will be collected. For large
spaces greater than 160 square feet and less than 25,000 square feet 5 samples will be
collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each
5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed on a tripod, not taped to existing surfaces and directed
downward at a 45 degree angle.
e. Air samples will be collected and analyzed in accordance with the procedures specified
in NIOSH 7400 Method followed by AHERA TEM. Air sampling cassettes need to be
monitored to ensure that cassettes are not clogging by monitoring flow rates. The minimum
sample volume required is 3600 liters. These air samples and copies of necessary
documentation shall be hand delivered daily to EMSL Laboratories at: 307 W. 38* St.,
New York, New York 212-290-0051.
f. Wipe samples will be collected at 10 percent ofthe residences where sampling only has
been requested, up to a maximum of 13 residences, as instructed by EPA. This sampling
will consist ofthe collection of3 wipe samples each for dioxin, total metals and mercury
(Note: a separate wipe sample is required for each parameter at each location). Metals
and mercury wipe samples will be collected in accordance with procedures specified in
HUD Appendix 13.1. Dioxin wipe samples will be collected in accordance with the
procedures specified in ASTMD 6661-01. Wipe samples and copies of necessary
documentation will be packed, sealed and shipped daily by courier for next day delivery
to Paradigm Analytical Laboratories at: 2627 Northchase Parkway SE, Wilmington NC
28405.
g- 24-hour tum-around time shall be specified for the analysis ofall samples collected using
the aggressive air sampling method. Standard tum-around time shall be specified for
analysis of modified aggressive air samples and wipe samples.
h. The Monitoring Contractor will document all the necessary information regarding sampling
activities, fill out all field logs, data sheets, and chain-of-custody forms. The Monitoring
Contractor will use F2L for all sample and chain-of-custody documentation. Samples
must be labeled and accompanied with completed chain-of-custody forms before shipping
to the designated laboratory. The label must include the EPA Project Tracking Number.
i. All information must be maintained using the secure EPA website (url, user name and
password to be provided by EPA). Information on sampling activities (date, sample ID)
shall be provided to EPA, via the website, within 24 hours ofcompletion ofsampling. All
data shall be maintained as confidential.
Deliverables
8
NYC-WTC_000139013
OCR can misread numbers and units. Confirm readings against the page image before using them.