existing surfaces.
g- Common spaces will be sampled without the use offorced air devices (fans, leafblowers
etc). For small spaces, less than 160 square feet, 3 samples will be collected. For large
spaces greater than 160 square feet and less than 25,000 square feet 5 samples will be
collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each
5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed on a tripod directed downward at a 45 degree angle and
not taped to existing surfaces.
h. Air samples shall be collected in accordance with the procedures specified in NIOSH
Method 7400 for PCM and 7402 forTEM. Air sampling pumps need to be monitored to
ensure pumps are not clogging by monitoring flow rates, the minimum sampling volume
required is 3600 liters.
1. siaatTation regarding sampling activities, fill
The contractor shall document all the necessary infi
out all field logs, data sheets, and chain-of-custody forms. The contractor shall use F2L for
all sample and chain-of-custody documentation. Samples must be labeled and accompanied
with completed chain ofcustody forms before shipping to the designated laboratory. The
label must include the EPA Project Tracking Number. Samples will be packed, sealed and
for analysis to EMSL laboratories at: 307 W. 38”’ St., New York, New York 212-290-
0051.
j- All information must be maintained using the secure EPA website(url, user name and
password to be provided by EPA). Dates for monitoring and/or cleaning shall be provided
to EPA and DEP electronically in an EPA approved format within 24 hours. Information on
sampling activities (date, sample ID) will be provided to EPA, via the website, within 24
hours of completion of evaluation.
Deliverables
The Project Monitor shall review all deliverables prior to submission to EPA. The review shall assure
that each deliverable is accurate and complete, technically sound, and free of clerical errors.
The Pro] ect Monitor shall record all post-cleaning information in the EPA Indoor Air database or
an agreed upon electronic format. This information shall include but, not limited to sampling technique
(aggressive or modified aggressive), visually cleaned (YZN), damage claim (Y/N), and post clean-up
status (pass/fail). Dates and times shall be associated with all activities including start and finish date.
Additional information shall be recorded include not limited to absence ofdust/debris, equipment
used (leafblower, fan etc.), size ofspace, start and completion dates for the cleaning, sample media,
flow media type, flow rates (start/final, flow rate (average). Time (start/finish). Total elapsed time
(min). Calculated sample volume (L), Pump fault, weather, units, QC samples (lot blank) sampling
dates, sample IDs, complete chain of custody, EPA Project Tracking Numbers and laboratory
address shall be entered into an agreed upon electronic format or website approved by EPA within
24 hours ofactivity. Dates and times shall be associated with all activities including start and finish
date.