HVAC inspection report, 295 Greenwich Street, Feb 2003
Machine-extracted title · confidence 95%
An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 295 Greenwich Street due to WTC dust.
2.1 Central Ventilation tem Visual I
Ventilation System Identification: I of 2
Location:
Loci 1CF-it i..jv Area Served:
1~A r L
Associatedmechanical room: clean Y N d Y N stored chemicals.'refuse Y
System Components Surface
Component
(NOTE: if component not present (NP), not DusV NVTC
found (NF) or inaccessible (1) please not
indicate in last column] Debris Dust
Present? present
Present? 4 not
found
Outside air intake: Location:
Accessible for inspection? 1' N (explain):
NP
lou •erg', ¢rates and'or screens
outside air duct N
outside air dam er(s)
Air handlin unit:
outside air mixine chamber
filter racks) N
filter media
blower.assaaably ircl. blower wheel, blower housing,-
noise attenuators air.anes, in-hue
blower housing acoustical linine
re-heat coils
heatin coils
cooline coils
re-heat coils
condensate d.a.':
su lv air lenum `
su I air lenum darn er(s
vibration collars
Supply air distribution:
Supply air du::s Et. t,-'tal In ft No. locations inspected
Specify type (circle) meta ibr us >ziass fined met masonry fibrous Qlass board
Accessible in-line fire dampers Est. total gry
No. locations inspected
Accessible rurnine vanes Est. total No. locations inspected
In-l:nom rehei'.~0001tne C^:~: ~:. tip:21 Gt)' ~•- '• _..•
•~. locations ins ected
—apply air diffusers
S Est. total qTy
Return air distribution. No locations inspected
Return air ducts Est. total In ft-__ 6 ___ No. locations inspected _(_
Specify type (circle): metal fibrous glass lined
metal mas nn' fi brous ¢lass board
ex-duct od
P.et'um air plenum Es:. total RA plenum
locations inspected I areas No.
Return air plenum darnper Est total qty___ _ ,
ins ected No. locations
Accessible in-line fire dampers Est. total qty
locations insnected No. 1
NYC-WTC 000134600
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000134600Source: NYC Law Department, mirrored locally
An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 275 Greenwich Street due to WTC dust.
5 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
An HVAC inspection report from Cole Consulting Corporation dated February 13, 2003, recommending cleaning of units at 275 Greenwich Street due to WTC dust.