WTC HVAC Inspection Report, 50 [Street], Feb 2003

Machine-extracted title · confidence 90%

Memo recommending cleaning of lobby and roof HVAC units at 50 [Street] due to WTC dust found during inspection.

NYC-WTC_000133793–000133805
Page image
Scanned page image, NYC-WTC_000133795
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual In Ventilation System Identification: ection Form L~ e1of2_ Location: ---- ---------- Lp(3~ APP _7 P1 ~Served: Associatedmechanicat room: clean Y N d y N stored chemicals/refuse C, System Components (NOTE: if component not present (NP), iy 1\ Component not found (NF) or inaccessible NN'TC not indicate in last column] (I) please 7Debrls 5 Dust present Present? not found Outside air intake: Location:

Accessible for inspection? Y N (explain):

lou •erss, grates and'or screens /JP outside air duct outside air dam er(s) Air handling unit: M SO outside air mixing chamber filter rack(s) filter media blower assembly incl, blower wheel, noise attenuators blower housing, air vanes, in-line

blower housing acoustical lining re-heat coils heating coils cooling coils re-heat coils condensate drain .an su I 'airplenum su 1 • air lenum dam er s) vibration collars NP Supply air distribution: NP Supply air ducts Est. total In ft /per No. locations inspected Specify type (circle) meta us lass Lined meta masonry fibrous glass board

Accessible in-line fire dam ers Est. total No. locations ins ected y Accessible turning vanes Est. total No. locations ins ected N In-line reheat'cooling coils Est. total No. locations ins ected N Su lv air diffusers Est. total No. locations ins ected N Return air distribution: Return air ducts Est. total In ft__J _ No. locations inspected__L Specify type (circle): metal fi brous glass lined metal masonr fibrous glass board flex -duct d Return air plenum Est. total RA plenum areas i No. locations ins ected Return air plenum damper Est. total ins ected qty No. locations Accessible in-line fire dampers Est. total qty locations inspected --- No.

NYC-WTC 000133795

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000133795Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000133629 · Box DEP Box 55

Memo from Cole Consulting recommending cleaning of HVAC components at 50 [Street] following visual inspection for WTC dust in February 2003.

Similar indexed content

NYC-WTC_000130428 · Box DEP Box 53

Memo from Cole Consulting Corporation recommending no HVAC cleaning at a building on the WTC site due to lack of WTC dust.

Similar indexed content

Compare copies and versions →