Ventilation System Evaluation Form, Nov 2003

Machine-extracted title · confidence 90%

A ventilation system evaluation form for a multi-use facility with 300 residential units and nine floors.

NYC-WTC_000132758–000132807
Page image
Scanned page image, NYC-WTC_000132775
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Inspection Form Page 1 of 2 Ventilation System Identification: Ul Location: n Area Served: GASF..NIrv- T 6R'S 6 A r" -j— f 2EA 2 Associatedmechanical room: clean Y N Y N stored chemicals/refuse Y N Surface Component System Components Dust/ WTC not [NOTE: if component riot present (NP), not found (NF) or inaccessible (I) please Debris Dust present indicate in last column] Present? Present? 4 not found

Inaccessible Outside air Intake: Location:

Accessible for inspection? Y J N (explain): Y (J

louver , rates and/or screens ' Y outside air duct %( nJ outside air damper(s) tJ Air handling unit: outside air mixing chamber AJ filter rack(s) (i filter media blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators blower housing acoustical lining nJ pre-heat coils heating coils (J cooling coils p4 n re-heat coils P condensate drain an supply air plenum supply air plenum damper(s) fJP vibration collars I, ) Supply air distribution: cc~~ Supply air ducts Est. total In ft d` C) C7 No. locations inspected__ Specify type (circle): eta us ass lined meta masonry fibrous glass board A) ex-duct woo

Accessible in-line fire dampers Est. total gty No. locations inspected pj Accessible_turning vanes Est. total No. locations ins ected In-line reheat/cooling coils Est. total gty No. locations inspected NP Supply air diffusers Est. total No. locations inspected n1 Return air distribution: Return air ducts Est. total In ft__________ No. locations inspected I Specify type (circle): eta fibrous glass lined metal masonry fibrous glass board . f flex-duct wood !

Return air plenum Est. total RA plenum areas__ No. locations ins ected Return air plenum damper Est. total qty No. locations inspected N Accessible in-line fire dampers Est. total qty No. locations ins ected P

NYC-WTC 000132775

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000132775Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117345 · Box DEP Box 46

January 30, 2003 letter from Athenica Environmental Services regarding HVAC and environmental inspections at 250 South End Avenue.

Similar indexed content

Compare copies and versions →