Ventilation system evaluation form, 49 Fulton Street, Jan 2003

Machine-extracted title · confidence 95%

Form documenting ventilation system types and facility details for a building at 49 Fulton Street.

NYC-WTC_000129218–000129268

Folder label: “49 FULTON STREET 1001290, 95/27

Page image
Scanned page image, NYC-WTC_000129220
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.1 Central Ventilation System Visual Inspection Form Pa e1of2 Ventilation System Identification: G_t4 V DT t Location: Area Served: J A rV 2 2i'( Associatedmechanical room: clean IY N ClryIIY N stored chemicals/refuse Y N Surface Component System Components Dust! WTC 4 not [NOTE: If component not present (NP), not found (NF) or inaccessible (I) please Debris Dust present indicate in last column] Present? Present? not 4 found 4 Inaccessible Outside air intake: Location:

Accessible for inspection? Y N (explain): iv T louver grates and/or screens ' ,J outside air duct wJ n

outside air damper(s) !J P Air handling unit: outside air mixing chamber ^j filter rack(s) filter media A! blower assembly incl. blower wheel, blower housing, air vanes, in-line noise attenuators N blower housing acoustical limit pre-heat coils N heating coils toP coolie coils NJ re-heat coils condensate drain pan rJ supply air plenum supply air plenum damper(s) N vibration collars NP Supply air distribution: Supply air ducts Est. total In ft 7 No. locations inspected_ Specify type (circle) fibrous glass lined metal Masonry fibrous Mass board ,/ /J flex-duct wood Accessible in-line fire dampers Est. total gty No. locations inspected N Accessible turning vanes Est. total gty No. locations inspected ;v In-line reheat/cooling coils Est. total No. locations ins ected Supply air diffusers Est. total gty t No. locations inspected A/ Return air distribution: Return air ducts Est. total In ft No. locations inspected I Specify type (circle): etsl fibrous glass lined metal masonry fibrous glass board flex-duct QQd Return air plenum Est. total RA plenum areas i No. locations ins ected 1 Return air plenum damper Est. total qty No. locations inspected Accessible in-line fire dampers Est. total qty No. locations inspected

NYC-WTC-000129220

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000129220Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →