NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 03-2744 New York City D.E.P. ELAP Lab Code: 11029 Analyte: FIBERS 59-17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Received: 3/24103 Flushing, NY 11373 NVLAP Lab Code: 101953 Date Analyzed: 3/24/03 Batch #: 0303A599 SUMMARY OF ANALYTICAL RESULTS - PCM Site: 114 Liberty Street, New York, NY

SAMPLE# COLLECTED DESCRIPTION! LOCATION TIME(min) VOLUME(L) FIBIFIELD RESULTS(f/cc) LAB #

001 Dining Room/ Stairway/ North Side/ OWA 600 3639.6 12/100 0.0016 23-March A 8577

002 Clean Room of Decon/ OWA 600 3639.6 16/100 0.0022 23-March A 8578

003 Entrance to Work Area/ Liberty Street Side/ OWA 600 3639.6 8/100 0.0011 23-March A 8579

004 Entrance to the Basement Stairway/ OWA 600 3639.6 10/100 0.0013 23-March A 8580

005 Entrance to the Work Area/ Center Street Side/ 600 3639.6 6/100 0.0008 23-March OWA A 8581

006 FIELD BLANK 0/100 23-March A 8582

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/ 100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 994 Instrumentation: Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). La a aC 1 IWa a Laboratory Director Report Date: March 28, 2003 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 31 of 32

NYC-WTC 000132000

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000132000Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →