JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 03-2744 New York City D.E.P. ELAP Lab Code: 11029 Analyte: FIBERS

10 59-17 Junction Blvd. Flushing, NY 11373 NIOSH and AIHA Lab Code: 100273 NVLAP Lab Code: 101953

SUMMARY OF ANALYTICAL RESULTS - PCM Date Received: Date Analyzed: Batch #: 3/24/03 3/24/03 0303A597

Site: 114 Liberty Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(L) FIBIFIELD RESULTS(f/cc) LAB#

001 During/ Inside Entrance to Bid.! Northern Side 600 3650 5/100 0.0007 21-March A -8563

002 During/ Personal Decon/ Clean Room 600 3650 3/100 0.0004<LOD 21-March A 8564

003 During! Inside/ Eastern Side of Bldg. 600 3650 15/100 0.0020 21-March A 8565

004 During/ Inside/ Entrance to Basement 600 3650 7/100 0.0009 21-March A 8566

005 During/ Inside of Bldg./ Ceader St. Entrance 600 3650 5/100 0.0007 21-March A 8567

006 FIELD BLANK 0/100 21-March A 8568

Sample Analysis omI: <LOD = Less than limit of detection which is 5.5 Fibers/ 100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, Augps~,1~ Instrumentation: U am c Iwa a Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Laboratory Director Report Date: April 1, 2003 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 14 of 19

NYC-WTC 000131992

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000131992Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →