NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 03-2744
New York City D.E.P. ELAP Lab Code: 11029 Analyte: FIBERS
59-17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Received: 3/20/03
Flushing, NY 11373 NVLAP Lab Code: 101953 Date Analyzed: 3/21/03
Batch #: 0303A589
SUMMARY OF ANALYTICAL RESULTS - PCM
Site: j 114 Liberty Street, New York, NY — -~
SAMPLE #
COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(L) FIBIFIELD RESULTS(flcc)
LAB#
001 Decon/ Clean Room 600 3650 41/100 0.0055
20-March
A 8466
002 Right Side of Decon/ Near Stairs 600 3650 35/100 0.0047
20-March
A 8467
003 Left Side of Decon/ Hallway! Access from Liberty 600 3650 13/100 0.0017
20-March Street
A 8468
004 By Entrance to the Basement 600 3650 37/100 0.0050
20-March
A 8469
005 Hallway/ Access from Cedar Street 600 3650 34/100 0.0046
20-March
A 8470
006 FIELD BLANK 0/100
20-March
A 8471
Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/ 100 Fields
VOID1 = H.C.P. ( High Concentration of Particles)
Positive Phase Contrast Microscopy (PCM)
VOID2 = Overloaded
Method of Sample Preparation and Analysis:
All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, ul4st,1994
Instrumentation:
3ula ac Iwa a
Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter).
Laboratory Director
Report Date: March 21, 2003
JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this
method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of
JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees
to seek no costs beyond the above.
Page 23 of 24
NYC-WTC 000131988