NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 03-2744 New York City D.E.P. ELAP Lab Code: 11029 Analyte: FIBERS 17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Received: 3/1212003 ushing, NY 11373 NVLAP Lab Code: 101953 Date Analyzed: 3/12/2003 SUMMARY OF ANALYTICAL RESULTS - PCM Batch #: 0303A509

Site: 114 Liberty Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB #

001 During/ Outside Work Area! Inside Restaurant! 720 3650.4 3/100 0.0004<LOD 12-March 1st Floor/ Near Liberty Street Entrance A 7434

002 During/ Outside Work Areal Clean Room of 720 3650.4 4/100 0.0005<LOD 12-March Personnel Decon A 7435

003 During/ Outside Work Area/ Stairwell to 2nd Floor/ 720 3650.4 4/100 0.0005<LOD 12-March Near Critical Barrier A 7436

4 During/ Outside Work Area/ Stairwell to 720 3650.4 5/100 0.0007<LOD March Basement/ Near Entrance 7437

005 During/ Outside Work Area/ Inside Restaurant/ 720 3650.4 4/100 0.0005<LOD 12-March 1st Floor/ Near Loading Dock Entrance A 7438

006 FIELD BLANK 0/100 12-March A 7439

Sample Analysis by: <LOD = Less than limit of detection which Is 5.5 Fibers/ 100 Fields Positive Phase Contrast Microscopy (PCM) VOIDI = H.C.P. (High Concentration of Particles) VOID2 = Overloaded Method of Samole Preparation and Analysis: All samples analyzed In accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 Instrumentation: ac i , & ° ✓ F , Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter). Gam Macfihiwala Laboratory Director

Report Date: March 18, 2003

S C Is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among ethod gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and allother limitations, this JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other claims arising out of liability and the client agrees to seek no costs beyond the above. Page 13 of 14

NYC-WTC 000131956

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000131956Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →