HVAC Inspection Report Memo, 118 Chambers Street, Feb 2003

Machine-extracted title · confidence 95%

Memo from Cole Consulting Corporation recommending no HVAC cleaning at 118 Chambers Street due to lack of WTC dust.

NYC-WTC_000130411–000130418
Page image
Scanned page image, NYC-WTC_000130414
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2.4 Passive Shaft/Duct Visual Inspection Form Page l of I Passive Shaft-Duct Identification: Location: _ Area Served:

System Components Surface Component Dust/ WTC not )NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Debris Dust present indicate in last column) Present? Present? c 5 not found

Outside air intake (if servicing supply air): inaccessible Location:

Accessible for inspection? Y N___(explain):

louver's. erates. screens or weather cap Exhaust outlet/louver (if servicing exhaust air): Location: D t=

Accessible for inspection? Y/N .(explain): ~f

louvers, grates, screens or eather cap : Supply air distribution (if servicing supply air): Supply air outlet(s) Est. total qty No. locations inspected__^ _ Specify shaft substrate (circle): mewl f Brous elas lined moral misonr. fibrous etas: board fler-duct ood Accessible fire dampers Est. total qr: No. 1r -ati n; inspected Pi es'mechanical equipment. etc. located in shaft p Return air distribution (if servicing exhaust air): Exhaust air inlet(s) Est. total qty ~ No. locations inspected 0 Specify shaft substrate (circle): met I fibrous class lined metal masonry fibo s c' h :J f':.• . Accessible fire dam ers Est. total c•; No. locations ins e.t•:d {~ . Pipes'meehanical equipment. etc. located in shaft Other (specify): Nn

Other Information: I. I

General impression (indicate recommendations for cleaning based on finding of W1'TC dust):

5 .J' (

rhE~: NP=not present:I\h = r,~; iuund:I=inaccessible• U=unknown I

NYC-WTC 000130414

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000130414Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000133629 · Box DEP Box 55

Memo from Cole Consulting recommending cleaning of HVAC components at 50 [Street] following visual inspection for WTC dust in February 2003.

Similar indexed content

NYC-WTC_000130428 · Box DEP Box 53

Memo from Cole Consulting Corporation recommending no HVAC cleaning at a building on the WTC site due to lack of WTC dust.

Similar indexed content

NYC-WTC_000133762 · Box DEP Box 55

Cole Consulting identifies impacted HVAC units at 50 [Street] requiring cleaning due to WTC dust found during a February 2003 inspection.

Similar indexed content

Compare copies and versions →