NYC 9/11 Public Portal Document
10/23/2002 PASC - Certificate ofAnalysis Page 5 of 5
Blank Method Blank Blank
Client ID: Spike# I Blank 10/12 Spike #1 Spike # I
Lab No.: %Recoveries 065469 02 065469 02 %Recoveries
Date Sampled: 12-Sep-2002
Component Units
Total Tetrachlorodibenzofurans pg - <3.7 1000
Total Pentachlorodibenzofurans - <4.5 5700 -
Total Hexachlorodibenzofurans - 5.1 9300 -
Total Heptachlorodibenzofurans - 5.2 4600 -
Octachlorodibenzofuran " - 19 5300 -
Total Tetrachlorodibenzo-p-dioxins - <4.3 1000 -
Total Pentachlorodibenzo-p-dioxins - <5.0 2700 -
Total Hexachlorodibenzo-p-dioxins - <4.8 7700 -
Total Heptachlorodibenzo-p-dioxins - 8.0 2500 -
Octachlorodibenzo-p-dioxin - 17 5000 -
Internal Recoveries %
2.3,7.8-T4CDF-13C12 62 86 92 92
2,3.7,8-T4CDD-I3Cl2 68 74 79 79
1,2,3,7,8-P5CDF-13C 12 61 90 102 102
1,2,3,7,8-P5CDD- 13C12 61 85 109 109
1,2,3,4,7,8-H6CDF-I 3C 12 97 113 98 98
1,2,3,6,7,8-H6CDD-13C 12 95 102 108 108
1.2.3.4.6.7,8-H7CDF- 13C 12 95 125 104 104
1,2,3,4,6,7,8-H7CDD-13C 12 96 117 III 111
OCDD-13C12 110 133 110 110
2,3,7,8-C14-Dibenzofuran (DB5) pg 95 <3.7 990 99
2,3,7,8-CI4-Dibenzo-p-dioxin 97 <4.3 1000 101
I,2,3,7,8-C15-Dibenzofuran 99 <4.3 2600 106
2.3,4,7,8-C15-Dibenzofuran 113 <4.7 3000 120
1,2,3,7,8-CI5-Dibenzo-p-dioxin 108 <5.0 2700 109
1,2,3,4,7.8-C16-Dibenzofuran 87 <1.8 2300 91
1.2,3,6,7,8-CI6-Dibenzofuran 93 2.7 2400 98
2.3,4.6.7.8-C16-Dibenzofuran 86 2.2 2500 99
1,2,3,7.8,9-CI6-Dibenzofuran 89 <4.7 2000 80
1.2.3.4,7,8-CI6-Dibenzo-p-dioxin 97 <4.8 2700 110
1,2,3,6,7,8-CI6-Dibenzo-p-dioxin 100 <4.8 2400 95
1,2,3.7,8,9-CI6-Dibenzo-p-dioxin 92 <4.7 2600 103
1,2,3,4,6.7,8-C17-Dibenzofuran 86 4.5 2200 89
1,2,3.4.7,8,9-C17-Dibenzofuran 85 <6.1 2400 96
1,2,3,4,6,7,8-C17-Dibenzo-p-dioxin 92 8.0 2500 100
1,2,3,4,6,7,8,9-C18-Dibenzofuran 91 19 5300 106
1,2,3,4.6,7.8.9-CI8-Dibenzo-p-dioxin 96 17 5000 101
2,3,7.8-TCDF (DB225) pg
Internal Recoveries %
2.3.7.8-TCDF- I 3C 12
TEQ based on Nato Factors pg
Client:Philip Analytical Services Inc Project:Misc.
NYC-WTC 000130151