M TC 1. Client • S S O C. S . N C

2. o c me:, PROJECT MONITOR LOG _ 4.,Project #: ~; ~,1. 5._1Nruk Area(.s.G_.__.. "y. Part 1 . ._._._._._._._._._._., Pu.._._~._._.V ._._.,, . r mac. 3. Project Address:. 4a. Task #: c- I: 8. Represent 9. Date: 6. Contractor: 7. Contractor's Foreman:

Tent-Containment Glovebagging Other Type of Project: Full-Containmet

Large (> 160 sq. ft.. 260 tin. ft. of ACM) Small (< 160 sq. ft.. 260 tin. It.) Size of Project: ,_ Prep Removal Cleaning Phase of Abatement: __ Pre-abatement Sampling Encapsulation Waste Load-out Finals

FULL-CONTAINMENT ABATEMENT

Work Area Location (floor, room, section): Yes (Indicate prep work performed in 1 - 10) N/A (If already completed) Preparation of Work Area: 2. Ceiling Poly: Yes No 1. Construction of Decon: Yes No No 4. Wall Poly Yes No 3. Critical Barriers (CBs): Yes 6. Floor Poly: Yes No 5. Removal to establish CBs: Yes No No 8. Pre-cleaning: __ Yes No 7. Negative air: Yes 10. Temporary Power: Yes No 9. Prep work completed: Yes _ No 12. Prep-Inspection Passes: Yes No (Explain why) 11. Other Yes _ No

Removal: Yes (Complete 1 - 5) __ N/A

Duct Insulation Fireproofing Ceiling Tile 1. Type of ACM: Pipe Insulation Transite Boards Floor Tile Other: Boiler Insulation 3. Amended water used during removal: Yes No , Yes No 2. Negative air pressure ≥ 0.02 in. of water: Yes No Yes No 5. Proper Decon procedures followed: 4. Critical barriers intact for shift's duration: Cleaning: Yes (Complete 1 - 6) N/A

2nd Stage 3rd Stage 2 12/12-hour waiting period after 1st cleaning: 1. 1st Stage Yes No cleaning: Yes No 4. 4/12-hour waiting period after 2nd cleaning: _ 3. Removal of 1st poly layer after 1st Yes No 6. 1/12-hour waiting period after 3rd cleaning: 5. Removal of 2nd poly layer after 2nd cleaning: Yes No

TENT-CONTAINMENT ABATEMENT

Work Area Location (floor, room, section): Yes (Indicate prep work performed in 1 - 6) N/A (If already completed) Preparation of Work Area:

2. Pre-cleaning: Yes No 1. Construction of Tent: Yes No 4. Negative Air: Yes No N/A 3. Construction of Decon: — Yes No 6. Pref-inspection passes: Yes _ No 5. Prep work completed: — Yes No

Removal: Ceiling Tile Pipe Insulation _ Duct Insulation Fireproofing 1. Type of ACM: Other: Boiler Insulation Transite Boards Floor Tile _

• 2. Method or Removal:

(If Glovebag RemovaI Check 3 throwgh 8) 3. Glovebags smoke-tested: Gross removal within tent

Yes _ No Glovebag removal within tent (check 3 through 8)

4. Glovebags attached to smooth surface: _ Yes No Removal included cleaning and encapsulation:__ Yes No Yes No 6. 5. Amended water used: Yes No Yes _ No 8. Glovebags vacuumed, double-bagged: 7. Open/damaged ends of insul. sealed: Continued on Back Form NY-8 1

NYC-WTC 000129706

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000129706Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →