DOH/DEP asbestos fact sheet draft, 105 Duane Street

Machine-extracted title · confidence 95%

Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.

NYC-WTC_000125845–000126009

Folder label: “105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER

Page image
Scanned page image, NYC-WTC_000125981
OCR text

OCR status: ok · source: pdftotext

NYC 9111 Public Portal Document

Conversion of TEM measurements of WTC dusts to the PCM measurements usedfor the health studies.

A problem, or perhaps more an uncertainty, in using Table 3 arises from the fact that the human health studies are correlated to asbestos that was measured by the PCM method, which does not detect smaller fibers. The WTC dusts were measured by EPA using the more sensitive TEM method, which does detect these smaller fibers.

Since TEM analyses of WTC dusts give higher reading of fibers/structures asbestos than a P .M reading, some would argue that all of the WTC asbestos levels should be divided by some number (made smaller) to make them comparable to the ATSDR studies which used PCM. For the WTC dusts, the ratio of TEM fibers/structures to PCM-equivalent fibers/structures was high' around 80 to 90."

I have chosen not to attempt any conversion of TEM measurements to PCM-equivalent measurements for several reasons. First, the older PCM measures used in studies cited the ATSDR may not, in fact, be smaller than a TEM measurement of the actual asbestos to which the humans were exposed. This is because PCM cannot distinguish between asbestos and other fibrous minerals. Thus, the studies of humans using PCM measurements may actually have overestimated true asbestos exposures because they included non-asbestos fibers. Also, the asbestos fibers to which persons were exposed in these older studies may not have included a substantial fraction of the smaller fibers like the WTC dusts.

Second, as a matter of policy, the federal EPA has issued no guidelines or standards recommending the use of such a conversion in asbestos risk assessments. If such a recommendation were to be issued, it would first undergo extensive internal and external peer review, and be subjected to due process through a notice and comment period. As an individual staff scientist, I would not take it upon myself to lower a ri

assessment until such final sk

guidance is issued. As prudent public policy, however, it is always valid for anyone to upgrade a risk assessment based on new, even if untested, data indicating a greater hazard.

Claim thatfine asbestos particles are not hazardous

Some may argue that the smaller WTC fibers are less hazardous than the larger fibers. To my knowledge, the federal EPA has not addressed this scientific theory and issued any guidance to discount any cancerous effects of fine asbestos fibers. If such a recommendation were to be issued, it would first undergo extensive internal and external peer review, and be subjected to due process through a notice and comment period. Until such time as this occurs, as a matter of prudent public health policy, it would be inappropriate to downgrade a risk assessment based on this theory. I have also been informed that EPA has no intention of downgrading the ri

based sk

on this theory.

- 10-

NYC-WTC 000125981

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125981Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →