additional 1,000 square feet of work area (or at a rate determined by the fire
safety representative).
7.6 Internal combustion engines may NOT be operated within the work site. No
gasoline or other flammable liquids may be stored in or adjacent to the work
area nor may flammable liquids or other substances be dispensed or handled
within or adjacent to the work area. The Contractor shall not bring flammable
liquidsisubstances onto the Owner's property without express, prior written
permission from the Owner(s).
7.7 Exits from the work areas and emergency exits shall be established in
accordance with applicable codes and regulations. Exits shall be checked
daily for any exterior blockage or impediments to egress.
7.7 Work area barriers, etc. shall be clearly marked with information concerning
fire exits, etc., so as to meet the requirements of this specification, the
Owner(s), and fire code/department.
SECTION FOUR: REQUIREMENTS FOR PROTECTIVE EQUIPMENT
1.0 Respiratory Protection
1.1 Respiratory protection shall be worn by all individuals inside the work area
from the initiation of the asbestos project until all areas have successfully
passed clearance air monitoring.
a) All respiratory protection shall be MSHA/NIOSH approved in
accordance with the provisions of 30 CFR Part 11. All respiratory
protection shall be provided by the Contractor and used by workers in
conjunction with the written respiratory protection program.
b) The Contractor shall provide all workers, foreman, superintendents,
authorized visitors and inspectors personally issued and marked
respiratory equipment approved by NIOSH and MSHA. When using
respirators with disposable filters, the Contractor shall supply
replacements after every shift.
c) Workers shall be provided with personally issued and individually
marked respirators. Respirators shall not be marked with any
instrument that will alter the fit of the respirator in any way. Only
waterproof identification markers will be used.
d) The Contractor shall ensure that the workers are qualitatively or
quantitatively fit tested for any negative pressure respirator by an
Industrial Hygienist initially and every six months thereafter with the
type of respirator he will be using. Qualitative fit testing may only be
used for half-mask respirators.
e) Whenever the respirator design permits, workers shall perform the
positive and negative air pressure fit test each time a respirator is
Prepared by JLC Environmental Consultants, Inc. Project No. 04-3271 Page 29
NYC-WTC 000125607