Asbestos Abatement Technical Specifications
For 130 Cedar Street, New York, NY
asbestos fiber concentrations inside and outside the work areas of a building
• prior to the start of abatement activities.
2.22 Clean Room: An uncontaminated area or room that is part of the
worker decontamination enclosure with provisions for storage of
workers' street clothes and protective equipment.
2.23 Clearance Air Monitoring: The employment of aggressive sampling
techniques using the volume of air collected to determine the airborne
concentrations of residual fibers. It is to be performed as the final abatement
activity.
2.24 Contractor: The State, any political sub-division of the State, a public
authority or any other governmental agency or instrumentality thereof, self
employed person, company, unincorporated association, firm, partnership or
corporation and any owner or operator thereof, which engages in an
asbestos abatement project.
2.25 Curtained Doorway: A device that consists of at least three overlapping
sheets of plastic over an existing or temporarily framed doorway. One (1)
sheet shall be secured at the top and left side, the second sheet at the top
and right side, and the third sheet at the top and left side. All sheets shall
have weight attached to the bottom to insure that the sheets hang straight
and maintain a seal over the doorway when not in use.
2.26 Decontamination Enclosure System (DES): A series of connected rooms,
separated from the work area and from each other by air locks and used for
the decontamination of workers, materials and equipment.
2.27 Demolition: The dismantling or razing of a building, including all operations
incidental thereto (except for asbestos abatement activities for which a
demolition permit from the New York City Building Departments is required).
2.28 Disturb: To alter or change, such as but not limited to the removal,
encapsulation, enclosure or repair of ACM.
2.29 Encapsulant (sealant) or Encapsulating Agent: A liquid material which can
be applied to an ACM and which temporarily controls the possible release of
asbestos fibers from the material by creating a membrane over the surface
(bridging encapsulation) or by penetrating into the material and binding its
components together (penetrating encapsulant).
2.30 Encapsulation: The coating or spraying of asbestos materials with a
sealant/encapsulating agent.
2.31 Enclosure: The construction of air tight walls and a ceiling between the
asbestos material and the facility environment, or around surfaces coated
with asbestos materials, or any appropriate and approved procedure that
prevents the release of asbestos materials.
•