Air sampling summary letter, 225 Rector Place, Jan 2002

Machine-extracted title · confidence 95%

Letter from environmental consultants summarizing ambient air sampling and cleanup activities at 225 Rector Place.

NYC-WTC_000123875–000124219

Folder label: “225 RECTOR PLACE Block: 16 Lot: 70 BIN: 1000053 210 SOUTH END AVENUE

Page image
Scanned page image, NYC-WTC_000124124
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

. 104 East 25th Street

TC va

t New York, New York 10010 www.atc-enviro.com ) 212.353.8280 ASSOCIATES Fax 212.353.8306 I N C.

November 17, 2001 ATC Associates Inc. 104 East 25th Street New York, NY 10010 Attn: Mr. Fred Burkhardt

Re: Report of TEM Analysis Dear Mr. Burkhardt:

Following are the results of transmission electron microscopy (TEM) analysis of air samples from our Group No. 5907:

Client: 225 Rector Place Project Name: 225 Rector Place, NY, NY Location: Various Sites Samples received: 11/17/01

These results will confirm and document the data to your office. The analyses were performed in transmitted today strict conformance with the methodology of the AHERA Final Rule (CFR October 30, 1987) for clearance of abatement sites. As indicated on the attached document, no asbestos structures were detected in any of the seventeen ambient samples submitted from the site. MMI TEM cassettes, Lot No. 00265916, were used. Unfortunately, was defective and was not analyzed. sample 2

Results reported as Struct/cc are a function of air volume collected . in the field and are, as such, not verifiable by this laboratory. This report may be reproduced only in its not without prior permission of this laboratory. If entirety and post-abatement inside samples pass, the response action may be been completed. considered to have The analyses were supervised by Dr. Michael A. Gorycki, Director of Electron Microscopy.

We are pleased to note that our TEM lab has received full accreditation from NVLAP, as is currently required for analysis of TEM air samples for AHERA projects, and recognized also approval under the NY State DOH ELAP program. These analyses were performed by ATC d/b/a ATC Associates Inc. Please contact me regarding any questions relating to these materials.

Very truly yours,

Michael A. Gorycki, Ph.D. Director of Electron Microscopy

NYC-WTC 000124124

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000124124Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000104321 · Box DEP Box 36

Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.

Cited alongside this record in an Ask answer

NYC-WTC_000161636 · Box DEP Box 42

Agenda listing panelists from federal agencies, unions, and city departments for a March 2004 conference on post-9/11 air quality.

Cited alongside this record in an Ask answer

Compare copies and versions →