Mazal Group LLC (100 John Street)
JLC Project # 01-2084
December 11, 2001
page 2
AIr SamDllnp Analysis and Proceduj
Introduction
Air sampling is defined as the process of measuring the fi
lter content of a known volume of air
entrained on a filter membrane over a specified period of time. Each
field designation and a JLC lab internal code to ensure proper, sample is cross-referenced by
of custody. Sample preparation takes place within an HEPA consistent handling through a chain
filter clean bench to avoid any possible
contamination.
Methodology
Test procedures for these samples conform to the National Institute of
Health (NiOSH) standards. Occupational Safety and
Air sampling was conducted at a level approximating the breathing zone of
persons anticipated to
be present in the area during normal operations. Samples collected should
typical airborne fiber concentration. represent the area's
All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm)
cellulose ester
membrane air sampling cassettes with conductive cowl.
Analytical Procedures
A section of the filter approximating twenty-five percent of the total filter was
removed
a pre-cleaned microscope slide and then exposed to approximately 250 microliter (NI) and placed on
of acetone
vapor. A single 3.0 - 3.5 pi drop of triacetin was applied and a clean #1.5 cover
slip was placed
upon the filter. The prepared slide was then heated on a slide heater until clarity
allowed analysis to
be conducted.
Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with
method, counting rule "A." NIOSH 7400
Phase Contrast Microscopy
JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast
equipped with a Walton-Beckett Graticule. Samples were analyzed by firstMicroscope, (PCM)
dissolving the filter
through a chemical process (described above) and then counting the fibers with
PCM at 400x
magnification, Phase contrast increases the light contrast between the object
thus enhancing the mlcroscopisfs ability to see fibers. Normally, 100 and the background,
microscopic fields or 100
fibers are counted, whichever occurs first.
Analytical Results
The "Summary of Analytical Results" represents the results of the
PCM limit of reliable quantification is less than 0.01 fibers/cubic analysis of the samples. The
do not meet these requirements, the entire work site must centimeter (f/cc) of air. If final tests
be re-cleaned and re-tested.