NOV. 15.2 1 5:45PM JLC ENVIRONMENTAL NO,752 P. 12/14
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, Now York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Milford Management Corp. roject No.: 01-2200
rP• ELAP Lab Code: 11029
Analyze: ASBESTOS
20 West 64th Street NIOSH and AIHA Lab Code: 100273
Date Recefv®d: 11115/01
New York, NY 10023 NVLAP Lab Code: 101953
Date Analyzed: 11/15101
SUMMARY OF ANALYTICAL RESULTS - PLM Batch#: 0111B439
Site: 377 Rector Street, New York, NY
SAMPLE#
DATE COLOR ASBESTOS TOTAL % OF
DESCRIPTION/LOCATION CONSTITUENTS
COLLECTED DETECTED? ASBESTOS
LAB #
CLIENT'S SAMPLE#
027 Roof/ Main Roof/ South Wing/ West Side/ BLACK NO 0% SYNF 12%
11/14/01 Sample of Roof Debris Dark FBGL 5%
12837 NFIB 83%
027E
028 Roof/ Main Roof/ South Wing/ Bulkhead/ BLACK NO 0% CELL 10%
11/14/01 Sample of Roof Debris Dark FBGL, 10%
12838 NFIB 80%
028E
029 Roof/ Water Tower Roof/ Sample of Roof BLACK NO 0% CELL 10%
11/14/01 Debris Dark FBGL 20%
12839 NFIB 70%
029E
'INSUFFICIENT MATERIAL SUBMITTED " TEM RECOMMENDED `~NOT ANALYZED POSITIVE STOP
Sample Analysis bv, ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Disperalon Staining (PLM-DS) CHRY = Chrysodle Asbestos PAPF = Paper Fiber
AMOS = Amoske Asbestos MINW = Mnerai Wool
CROC = Crocldol$a Asbestos FBGL = Fiberglass
ACTN AcUnoilte Asbestos SYNF = Synthetic Flbera
All samples were prepared and Analyzed In accordance with the EPA TREM = Treniollta Asbestos
'Method for the Determination of Asbestos In Bulk Building Materials' CELL = Cellulose
ANTH = Anthophyilte Asbestos NFIB r, Non-Fibrous
USEPAI 6001Rr93/116, July 1903.
ORGM m OrgerMc Matedet
WOLL = Wotlestonite
is %i ariation: HSHR a Horse Hair
Olympus PLM, Model BH-2NM Stereomicroscope. Model OTHR = Other
VMZ1x-4x. Gulam Machhiwala
Laboratory Director
Analytcal results reflect the make tip of Or rriatedals only In the areas sampled. This `summary of Analytical Results" shall not be reproduced except in full without the written
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any ?Agency of the U.S, QovemmenL ThIs method Is not applicable to
samples conq(ning large amounts of One fibers below the reeoludon of the light mIFtgecope. The value of1h(s method Is limited to the quantitative Identification of asbestos
and the sertmt-quangtatwe determinadon of asbestos content of bulk samples. expressed as a perGantage of the protected area. Quandtadon of asbestos content was
deterrillned with a visual volume estlmata, a calibrated visual area esgrnate, and(or point couhdng procedure. CAUTION; Other fibers with optical propertIes similar to asbestos
may give Pon** Interferences and will be considered asbestos under This methodology. Also, PLM Is riot consistently reliable in detecting asbestos In floor coverings and
similar non-idebie organleallybotad materials, Guantttatfve Eransmiaslon electron microscopy Is currently the only method that can be tiseel to determine 9 this material con be
considered or treated as noon.asbestoa containing.
Page 2 of 2
11/15/01 THU 18:47 (T%/R% NO 53911
NYC-WTC 000120706
OCR can misread numbers and units. Confirm readings against the page image before using them.