NYC-WTC_000095173
Letter dated February 19, 2002 summarizing clean-up activities and restoration efforts at 20 Vesey Street.
4 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗Summary of visual assessments and environmental testing for asbestos at 280 Rector Place conducted shortly after September 11.
NYC-WTC_000120550–000120602Folder label: “280 RECTOR PLACE Block: 16 Lot: 7506 BIN: 1065199 295 West Thames Street, The Soundings”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ACS Environmental Services, Inc. Ambient Air Quality Testing Results The Soundings 280 Rector Place, New York, NY
SUMMARY TABLE OF AIR SAMPLES COLLECTED Date Collected Sample ID # Sample Location Total Structure Density
10/05/01 0225-29-1 Unit; PII <16.7 struc/sq.mm.
0225-29-2 Center of Lobby <16.7 struc/sq.mm.
10/29/01 0225-31-1 Outside Entrance To Building <14.3 struc/sq.mm.
0225-31-2 Unit; PSI 14.3 struc/sq.mm.
0225-31-3 Fourth Floor Corridor 14.3 struc/sq.mm.
11/05/01 0225-31-6 Unit L_PII _ <16.7 struc/sq.mm.
0225-31-7 Seventh Floor Corridor <16.7 struc/sq.mm.
0225-31-8 Outside Entrance To Building <16.7 struc/sq.nun.
11/12/01 0225-31-11 Outside Entrance To Building <16.7 struc/sq.mm.
0225-31-12 Unit;.-PII <16.7 struc/sq.mm.
0225-31-13 Eighth Floor Corridor 16.7 struc/sq.mm.
11/19/01 0225-31-16 Outside Entrance To Building <16.7 struc/sq.mm.
0225-31-17 Unit! PII I <16.7 struc/sq.mm.
0225-31-18 Second Floor Corridor <16.7 struc/sq.mm.
The laboratory analytical reports are attached. Table I represents a summary of all pertinent information used for the structure (fiber) density and concentration calculations. Included are the size of each structure counted, the structure density and concentration, type of asbestiform material detected and the analytical sensitivity, which represents the concentration by the detection of one structure in the TEM structure count. Copies of the asbestos count sheets are included.
Should you have any questions or if we may be of further assistance, please do not hesitate to contact the undersign.
Reported by,
6 Louis~'Iliano Senior Project Manager ACS Environmental Services, Inc.
NYC-WTC 000120578
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000095173
Letter dated February 19, 2002 summarizing clean-up activities and restoration efforts at 20 Vesey Street.
4 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123875
Letter from environmental consultants summarizing ambient air sampling and cleanup activities at 225 Rector Place.
7 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098346
Cover page for a report containing TEM results and chain of custody documents for airborne asbestos monitoring.
4 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104321
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
4 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131492
Chain of custody and cover letter for transmission electron microscopy analysis of air samples from apartments at 125 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105698
A document label identifying the location as 140 Broadway and 70 Liberty Street with a unique NYC-WTC tracking number.
5 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105069
Cover letter enclosing air and bulk sampling results for 86 Trinity Place, 22 Thames, and 65 Broadway.
6 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106270
Letter confirming facade asbestos testing and subsequent cleaning at 153 Chambers Street.
6 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095084
Letter from American Stock Exchange enclosing air and bulk sampling reports for Trinity Place properties dated late 2001.
5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000102767
Cover letter and summary of ambient air sampling and cleanup activities at 400 Chambers Street from 2002.
6 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095120
Chain of custody document for air and bulk sampling results at the Exchange site dated October 2001.
4 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095478
Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.
5 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000120641
Laboratory report on ambient air samples collected in apartments and common areas of 333 Rector Place during September 24-26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000123875
Letter from environmental consultants summarizing ambient air sampling and cleanup activities at 225 Rector Place.
Cited alongside this record in an Ask answer
NYC-WTC_000120549
Summary of visual assessments and environmental testing results indicating no asbestos abatement was required at 280 Rector Place.
Filed in the same folder
NYC-WTC_000095173
Letter dated February 19, 2002 summarizing clean-up activities and restoration efforts at 20 Vesey Street.
Similar indexed content
NYC-WTC_000098346
Cover page for a report containing TEM results and chain of custody documents for airborne asbestos monitoring.
Similar indexed content