NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/21 SOUTH END AVENUE Block: 16 Lot: 7509 BIN: 1075698 300-390 South Thames Street, The Regatta
Document / 16 pages

Dust, air and water test results summary, 21 South End

Machine-extracted title · confidence 95%

Letter summarizing asbestos dust, air, and sanitary water testing results for apartments and common areas at 21 South End Avenue.

NYC-WTC_000120368–000120383

Folder label: “21 SOUTH END AVENUE Block: 16 Lot: 7509 BIN: 1075698 300-390 South Thames Street, The Regatta

Page image
Scanned page image, NYC-WTC_000120369
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Oct 12 01 03:09p ACS Environmental 7169986373 p.10 4

SCIENTIFIC LABOR4TORIIES,INC. 117 EAST 30TH STREET NEW YORK, NY 10016 TEL: (212) 679-8600 • FAX: (212) 879-9382 Fos.ssRvrcxswrmxrsxrALauaaamnras

PLM Bulk Asbestos Report ACS Environmental Services, Inc. Date Received 09/21/2001 SciLab Job No. 201092684 Attn: Louis Illiano Date Examined 09/21/2001 P.Q. # Thomas Swietek 2081 Homecrest Avenue Page 1 of 1 Brooklyn, NY 11229 RE: Thomas Swietek; The Regatta Condominium, 21 South End Avenue, New York, NY 10280

Client No. I HGA Lab No. Asbestos Present Total % Asbestos r BHS-02 201092684-01 Yes <1 % Location: 21 South End Avenue, Apt . PII

Description: Grey, Heterogeneous, Dust Asbestos Types: Chrysotilo <1.0 % Other Material: Cellulose 7.0 90, Fibrous glass 35. %, Non-fibrous >57. %

Reporting Notes: materials presentf f f (1) Composite analysis results for het rogenuus debris samples may be highly variable due to inhomogenities in Analyzed by: Jonathan Teda "'NADlNSD = no asbestos detec NA = not analyzed; NAPS = analyzed / positive stop; PLM Bulk Asbestos Analysis not

by EPA 600/M4-82-020 per 40 CFR 763 (NVLAP Lab #200546-0) and ELAP PLM Analysis Protocol 198.1 for New York sao plos (NYSDOH ELAP Lab # 11480); Note: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. TEM is curreatly the only method that can be used to determine if this material can be considered or treated as non-asbestos -containing in New York State (also see EPA Advisory for floor tile, ER 59, 146, 811/94). National Institute of Standards and Technology Accreditation requirements mandate that this report trust not be 38970, reproduced except in f Ii without the approval of the laboratory. This PLM report relates ONLY to the items tested. A(HA# 102843; VT Cart# 10055

Reviewed By: __ _ ---

NYC-WTC 000120369

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000120369Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →