NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 02/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083378
Document / 123 pages

Chain of custody form for bulk sampling and air monitoring,

Machine-extracted title · confidence 90%

Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.

NYC-WTC_000095208–000095330

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083378”

Page image
Scanned page image, NYC-WTC_000095243
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SCIENTIFIC , LABORA ATO II$r INC. 117 EAST 30TH STREET NEW YORK, NY 10016 TEL: (212) 679-8800 • FAX: (212) 679-9392 PULL SRUVtQWMIONMVITAL L4.ORA15araS

PLM Bulk Asbestos Report American Lead Consultants Date Received 10/05/2001 SciLab Job No. 201101479 Attn: Josh Sarrett Date Examined 10/05/2001 P.O. # Lefrak Organization 115 West 30th Street ELAP Number 11480 Page 1 of 1 Suite 1108 RE: Lefrak Organization; Bldg. 400, 375 South End Avenue New York, NY 10001

Lab No. Asbestos Present Total % Asbestos Client No. / HGA / 1`##19 201101479-01 Yes • Bedroom Floor—'"'~ Location: Apty1~0

Description: C-icy, Heterogeneous. Debris Asbestos Types: Chrysotile <1. % 30. 96. Other Material: Animal hair Trace. Cellulose 5. %, Fibrous glass Non-fibrous >64. %

Reoortin Notes: ro e us debris samples may highly vanable due to inhomogeaities in materials present (1) Composite analysis results for Analyzed by: Bella Chernis not analyzed / positive stop. PLM Bulk Asbestos Analysts -NAD/NSD = no asbestos detected; NA = not analyzed; NAPS = #200546-0) turd M-AP PLM Analysis Protocol 198.1 for New York by EPA 60o/M4-82.020 per 40 CFR 763 (NVLAP Lab consistently reliable in detecting asbestos in floor coverings and samples (NYSDOH FLAP Lab # 11480); Note: PLM not is materials. TEM is currently the only method that can be used to determine if this material similar non-friable organically bound New York State (also see EPA Advisory for floor tile. FR 59. 146. can be considered or treated as non-asbestos-containin8 in Accreditation requirements mandate that this report must not be 38970. 8/1/94). National Institute of Standards and Technology This PLM report relates ONLY to the items tested. AIHA# is reproduced except in fltll without the approval of 102843; VT Cert# AL016055 the laboratory.

Reviewed By:

NYC-WTC 000095243

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095243Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000095478 · Box DEP Box 02

Cover page for an air monitoring and bulk sampling report for Building #200 at 375 South End Avenue.

Cited alongside this record in an Ask answer

NYC-WTC_000121516 · Box DEP Box 48

Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

Cited alongside this record in an Ask answer

Compare copies and versions →