NYC 9/11 Public Portal Document
I SCIENTIFIC LAHORATOR/ES, INC.
117 EAST 30TH STREET
NEW YORK, NY 10016
TEL: (212)679-8600• FAX:(212)679-9392
PULL SERVICE ENVIRONMENTAL LABORATORIES
—1
P
PLM Bulk Asbestos Report
Li Applied Technology Services, Inc. Date Received 03/15/2002 SciLab Job No. 202032592
Attn: Steve Vanderwoude Date Examined 03/17/2002 P.O. # A02042
240 North Avenue ELAP Number 11480 Page 3 of 3
New Rochelle, NY 10801 RE• A02042
Reporting Notes:
(1) Positive samples (<10%) analyzed by EPA Point Count Method (400 points).
(2) Composite analysis results for heterogenous debris sam les may be highly variable due to inhomogenities in materials presen
Analyzed by: Bella Chernis
*NAD/NSD = no asbestos detected; A = not analyzed; NA/PS = not analyzed / positive stop; PLM Bulk Asbestos Analysis
by EPA 600/M4-82-020 per 40 CFR 763 (NVLAP Lab #200546-0) and EI,AP PLM Analysis Protocol 198.1 for New York
samples (NYSDOH ELAP Lab # 11480); Note: PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material
can be considered or treated as non-asbestos-containing in New York State (also see EPA Advisory for floor tile, FR 59, 146,
be
38970, 8/1/94). Natio al Institute of Standards and Technology Accreditation requirements mandate that this report must not
reproduced except i 11 without the a royal o the aboratory. This PLM report relates ONLY to the items tested. AIHA#
' 102843; VT Cert# AL016055
Reviewed By:
I
ri
I
I
I
NYC-WTC 000097534
OCR can misread numbers and units. Confirm readings against the page image before using them.