- qtr

e LC - .J The First Choice for Environmental Testing & Consulting

October 16 2001

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280 Via Facsimile

Subject - Gateway Plaza Building #400

Gentlemen:

been retained to perform bulk sampling, ALC Environmental Incorporated (ALC) has the EP.4 Protocol to determine the visual assessments & air monitoring according to apartment in the building presence of asbestos at the above referenced project. Every Any area where visible dust and was assessed by our inspectors for dust and debris. sample, which was then sent to a third debris was found, ALC's inspectors took a bulk most cases there was insufficient debris to Y parry independent laboratory for analysis. In Additionally, air sampling was L

sample and a visual assessment only was performed. building. crformed using TI M Methodology on every floor in the and analyzed at building 400. Twelve (12) initial background air samples were collected contrast microscopy (PCM) and two (2) Twelve (12) samples were analyzed via phase Microscopy (TEM). All were below the were analyzed via Transmission Electron permissible limits: fifty eight (158) bulk samples and Based on EPA Guidelines, we collected one hundred Methodology. One (1) sample analyzed them via Polarized Light Microscopy (PLM) above the regulatory limits of I `no. collected from one apartment was found to be slightly limits upon further analysis at a second . Zero 0 were found to be above the regulatory certified asbestos abatement laboratory for quality control purposes. However, clean the specific apartment contractors hired independently by the owner, were used to sampling. All air samples were found and the areas were cleared by ALC via TEM air the tenants where this cleaninp took to be well below the permissible limits and place have been notified of the clearance. the building. The air sampling and ALC then collected air samples on every floor in City Regulations pertaining to analysis was done utilizing applicable Federal, State and NESHAPS (40 CFR PART asbestos to include Federal OSHA (29 CFR 1926.58) EPA CFR PART 763) Asbestos 61), AND TSCA TITLE II AHERAIASHARA (40 Industrial Code Rule 56 and the Regulations; the New York State Department of Labor Protection Title 15 Asbestos Regulations. New York City Department of Environmental

:`212.279.6747 10001 • 212.279.1001 • 888 466 3620 • Fa 'Oth Street •. 11th Floor +New York, New York 215.732 9°9 • 888.789 8378 Fax 215 732.955 ace: The Bellevue • Suite 600 • 200 S. Broad Streci • Philadelphia. PA 19102 • wtivw.ALCEnvironmental.iom

NYC-WTC 000117509

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117509Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →